ArticleBMC neurology2021
Noninvasive real-time assessment of intracranial pressure after traumatic brain injury based on electromagnetic coupling phase sensing technology.
Article in BMC neurology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Dynamic cerebral blood flow assessment based on electromagnetic coupling sensing and image feature analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Non-Invasive Intracranial Pressure Monitoring.Journal of clinical medicine · 2023Review
- Pulmonary infection in traumatic brain injury patients undergoing tracheostomy: predicators and nursing care.BMC pulmonary medicine · 2022Article
- Early assessment of acute ischemic stroke in rabbits based on multi-parameter near-field coupling sensing.Biomedical engineering online · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
backgroundTo investigate the feasibility of intracranial pressure (ICP) monitoring after traumatic brain injury (TBI) by electromagnetic coupling phase sensing, we established a portable electromagnetic coupling phase shift (ECPS) test system and conducted a comparison with invasive ICP.
methodsTBI rabbits' model were all synchronously monitored for 24 h by ECPS testing and invasive ICP. We investigated the abilities of the ECPS to detect targeted ICP by feature extraction and traditional classification decision algorithms.
resultsThe ECPS showed an overall downward trend with a variation range of - 13.370 ± 2.245° as ICP rose from 11.450 ± 0.510 mmHg to 38.750 ± 4.064 mmHg, but its change rate gradually declined. It was greater than 1.5°/h during the first 6 h, then decreased to 0.5°/h and finally reached the minimum of 0.14°/h. Nonlinear regression analysis results illustrated that both the ECPS and its change rate decrease with increasing ICP post-TBI. When used as a recognition feature, the ability (area under the receiver operating characteristic curve, AUCs) of the ECPS to detect ICP ≥ 20 mmHg was 0.88 ± 0.01 based on the optimized adaptive boosting model, reaching the advanced level of current noninvasive ICP assessment methods.
conclusionsThe ECPS has the potential to be used for noninvasive continuous monitoring of elevated ICP post-TBI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.