How low can you go? A CBCT dose reduction study.

Arthur J Olch, Parham Alaei

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed
4.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 31 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Low-dose CBCT image reconstruction: a review.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2026
    Review
  6. Article
  7. Article
  8. [Advances in low-dose cone-beam computed tomography image reconstruction methods based on deep learning].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Arthur J OlchRadiation Oncology Program, Children's Hospital Los Angeles, Los Angeles, CA, USA.ORCID https://orcid.org/0000-0002-0814-5891
Parham AlaeiDepartment of Radiation Oncology, University of Minnesota, Minneapolis, MN, USA.ORCID https://orcid.org/0000-0003-4847-9068
Children's Hospital of Los Angeles · USUniversity of Minnesota · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeCone beam computed tomography (CBCT) is often used for patient setup based solely on bony anatomy. The goal of this work was to evaluate whether CBCT dose can be lowered to the level of kV image pair doses when used for bony anatomy-based IGRT without compromising positioning accuracy.

methodsAn anthropomorphic phantom was CT scanned in the head, head and neck, chest, and pelvis regions and setup on the linear accelerator couch with the isocenter near the planned location. Cone beam computed tomographies were performed with the standard "full dose" protocol supplied by the linac vendor. With sequentially lowering the dose, three-dimensional (3D) matching was performed for each without shifting the couch. The standard kV image pair protocol for each site was also used to image the phantoms. For all studies, six degrees of freedom was included in the 2D or 3D matching to the extent they could be employed. Imaging doses were determined in air at isocenter following the TG-61 formalism.

resultsCone beam computed tomography dose was reduced by 81-98% of the standard CBCT protocol to nearly that of the standard kV image pair dose for each site. Relative to the standard CBCT shift values, translational shifts were within 0.3 and 1.6 mm for all sites, for the reduced dose CBCT and kV image pair, respectively. Rotational shifts were within 0.2 degree and 0.7 degrees for all sites, for the reduced dose CBCTs and kV image pair, respectively.

conclusionFor bony anatomy-based image guidance, CBCT dose can be reduced to a value similar to that of a kV image pair with similar or better patient positioning accuracy than kV image pair alignment. Where rotations are important to correct, CBCT will be superior to orthogonal kV imaging without significantly increased imaging dose. This is especially important for image guidance for pediatric patient treatments.

Indexed as

Drug TaperingSpiral Cone-Beam Computed TomographyChildCone-Beam Computed TomographyHumansParticle AcceleratorsPhantoms, ImagingCBCTimage gentlyimaging dose

Identifiers

PMID33450139
PMCPMC7882101
OpenAlexW3120090110

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.