ArticleJournal of applied clinical medical physics2021
Fetal radiation dose of four tube voltages in abdominal CT examinations during pregnancy: A phantom study.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 19 citations in OpenAlex.
- Development and validation of a pregnant phantom with adjustable fetal presentation for region-specific fetal radiation dose assessment during pelvic radiography.Journal of applied clinical medical physics · 2026Article
- Effect of 70-kVp chest CT on surface dose at the mammary gland level in a neonatal phantom under matched CTDIvol conditions.Radiological physics and technology · 2026Article
- Evaluation and implementation of an independent Kilovoltage X-ray-based imaging platform for carbon ion radiotherapy.Journal of applied clinical medical physics · 2026Article
- Reducing Radiation Dose in Computed Tomography Imaging of Adolescent Idiopathic Scoliosis Using Spectral Shaping Technique with Tin Filter.Tomography (Ann Arbor, Mich.) · 2025Article
- Feasibility of 100 kV Low-voltage Bone Mineral Density Measurement with Quantitative CT: Phantom and Clinical Research.Calcified tissue international · 2025Article
- Analysis of material composition and attenuation characteristics of anthropomorphic torso phantoms for dosimetry using dual energy CT technology.Physical and engineering sciences in medicine · 2025Article
- Out-of-field dose assessment for pencil beam scanning proton radiotherapy versus photon radiotherapy for breast cancer in pregnant women.Physics and imaging in radiation oncology · 2025Article
- 3D printing of realistic body phantoms: Comparison of measured and simulated organ doses on the example of a CT scan on a pregnant woman.Medical physics · 2024Article
- Influence of spectral shaping and tube voltage modulation in ultralow-dose computed tomography of the abdomen.BMC medical imaging · 2024Article
- Development and validation of the low-cost pregnant female physical phantom for fetal dosimetry in MV photon radiotherapy.Journal of applied clinical medical physics · 2024Article
- Evaluation of radiation dose for inferior vena cava filter placement during pregnancy: A comparison of dosimetry and dose calculation software.Journal of applied clinical medical physics · 2023Article
- Tin filter compared to low kV protocols - optimizing sinonasal imaging in computed tomography.PloS one · 2023Article
- What are useful methods to reduce occupational radiation exposure among radiological medical workers, especially for interventional radiology personnel?Radiological physics and technology · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
Abstract
This study aimed to compare the dose and noise level of four tube voltages in abdominal computerized tomography (CT) examinations in different abdominal circumference sizes of pregnant women. Fetal radiation doses were measured with two anthropomorphic pregnant phantoms and real-time dosimeters of photoluminescence sensors using four tube voltages for abdominal CT. The noise level was measured at the abdomen of two anthropomorphic pregnant phantoms. In the large pregnant phantom, the mean fetal doses performed using 120 and 135 kV were statistically significantly lower than the lower tube voltages (P < 0.05). In the small pregnant phantom, the mean fetal dose performed by 100, 120, and 135 kV was significantly lower than the lowest tube voltage tested (P < 0.05). The ratios of the peripheral mean dose to the centric mean dose showed that the ratios of 80 kV were the highest and those for 135 kV were the lowest in both pregnant phantoms. The ratios of the peripheral mean dose to the centric mean dose decreased as the tube voltage increased. Compared with low tube voltages, high tube voltages such as 120 and 135 kV could reduce radiation doses to the fetus without compromising the image uniformity in abdominal CT examinations during pregnancy. On low tube voltage protocols, the dose near the maternal skin surface may be increased in large pregnant women because of reduced penetration of the x rays.