Performance of four dual-energy CT platforms for abdominal imaging: a task-based image quality assessment based on phantom data.

J Greffier, S Si-Mohamed, D Dabli, H de Forges, A Hamard, P Douek, J P Beregi, J Frandon

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

J GreffierDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France. joel.greffier@chu-nimes.fr.ORCID http://orcid.org/0000-0002-1735-5129
S Si-MohamedDepartment of Radiology, Hospices Civils de Lyon, 69500, Lyon, France.
D DabliDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
H de ForgesDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
A HamardDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
P DouekDepartment of Radiology, Hospices Civils de Lyon, 69500, Lyon, France.
J P BeregiDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.
J FrandonDepartment of Medical Imaging, CHU Nimes, Medical Imaging Group Nimes, EA 2415, Univ Montpellier, Bd Prof Robert Debré, 30029, Nîmes Cedex 9, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo compare the spectral performance of dual-energy CT (DECT) platforms using task-based image quality assessment based on phantom data. MATERIALS AND

methodsTwo CT phantoms were scanned on four DECT platforms: fast kV-switching CT (KVSCT), split filter CT (SFCT), dual-source CT (DSCT), and dual-layer CT (DLCT). Acquisitions on each phantom were performed using classical parameters of abdomen-pelvic examination and a CTDI

resultsThe noise magnitude decreased from 40 to 70 keV for all DECT platforms, and the highest noise magnitude values were found for KVSCT and SFCT and the lowest for DSCT and DLCT. The average NPS spatial frequency shifted towards lower frequencies as the energy level increased for all DECT platforms, smoothing the image texture. TTF values decreased with the increase of keV deteriorating the spatial resolution. For both simulated lesions, higher detectability (d' value) was obtained at 40 keV for DLCT, DSCT, and SFCT but at 70 keV for KVSCT. The detectability of both simulated lesions was highest for DLCT and DSCT.

conclusionHighest detectability was found for DLCT for the lowest energy levels. The task-based image quality assessment used for the first time for DECT acquisitions showed the benefit of using low keV for the detection of contrast-enhanced lesions. KEY POINTS: • Detectability of both simulated contrast-enhanced lesions was higher for dual-layer CT for the lowest energy levels. • The image noise increased and the image texture changed for the lowest energy levels. • The detectability of both simulated contrast-enhanced lesions was highest at 40 keV for all dual-energy CT platforms except for fast kV-switching platform.

Indexed as

Radiography, Dual-Energy Scanned ProjectionTomography, X-Ray ComputedAbdomenHumansPhantoms, ImagingSignal-To-Noise RatioComparative studyPhantoms, imagingRadiography, dual-energy scanned projectionTomography, X-ray computed

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.