Evidence map›Paper›PMID 33449142›Full record

ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

Femoral matched tibia component rotation has little effect on the tibial torsion after total knee arthroplasty.

Ji Hoon Bae, Ja-Woon Lee, Soo-Hyun Kim, Sang-Gyun Kim, Young-Sik Jeon, Jeong Seok Choi

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.4field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 2 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 2 countries.

Ji Hoon BaeDepartment of Orthopedic Surgery, Korea University Guro Hospital, Korea University College of Medicine, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Republic of Korea. osman@korea.ac.kr.ORCID http://orcid.org/0000-0002-6390-0378
Ja-Woon LeeDepartment of Orthopedic Surgery, Korea University Guro Hospital, Korea University College of Medicine, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Republic of Korea.
Soo-Hyun KimDepartment of Orthopedic Surgery, Naval Maritime Medical Center, Jinju, 51640, Republic of Korea.
Sang-Gyun KimDepartment of Orthopedic Surgery, Korea University Ansan Hospital, Korea University College of Medicine, Ansan, 15355, Republic of Korea.
Young-Sik JeonDepartment of Orthopedic Surgery, Korea University Guro Hospital, Korea University College of Medicine, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Republic of Korea.
Jeong Seok ChoiDepartment of Orthopedic Surgery, Korea University Guro Hospital, Korea University College of Medicine, 148 Gurodong-ro, Guro-gu, Seoul, 08308, Republic of Korea.
Korea University Medical Center · KRKorea Maritime Institute · KRKorea University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTibiofemoral synchronization technique matches the rotational alignment of the tibial component to the femoral component during the total knee arthroplasty (TKA). The rotational axis of the proximal tibia can be changed by this technique, which affects tibial torsion postoperatively. The purpose of this study was to investigate whether the tibiofemoral synchronization technique affect the tibial torsion, and the lower limb rotation after primary TKA. It was hypothesised that the tibial torsion would change after primary TKA.

methodsNinety-three posterior stabilised TKAs from 89 patients were included from January 2017 to December 2018. Mechanical hip-knee-ankle axis (mHKA), in plain radiographs, femoral anteversion, tibial torsion, femoral neck-malleolar angle (FNMA), and rotational alignment of the femoral and the tibial components in pre- and postoperative CT scans were measured by two blinded observers. The primary outcome was a postoperative change in femoral anteversion, tibial torsion and FNMA. Clinical outcomes were evaluated using the American Knee Society Knee Score (AKSKS)/Function Score (AKSFS), and Oxford Knee Score (OKS) preoperatively and at 1 year after TKA. Patients' perception of changes in the foot progression angle after TKA was investigated. Statistical significance was set at p < 0.05.

resultsThe mean rotational mismatch between the femoral and the tibial component was 0.6 ± 3.2°. There was a significant decrease in femoral anteversion (9.5 ± 6.7° vs. 5.2 ± 6.6°, p < 0.001), and a significant increase in the FNMA (17.6 ± 9.7° vs. 21.8 ± 10.5°, p = 0.005) after TKA, while no significant change in tibia torsion was observed (25.4 ± 8.8° vs. 24.9 ± 9.3°, p = 0.739). AKSS (37.8 ± 15.1 vs. 92.8 ± 8.8, p < 0.001), AKSFS (53.9 ± 18.1 vs. 89.9 ± 5.3, p < 0.001), and OKS (18.0 ± 7.3 vs. 39.9 ± 4.8, p < 0.001) were significantly improved at 1 year after TKA. Ten knees (11%) had changes in tibial torsion greater than ± 10° postoperatively. Four of five patients who had changes in FNMA greater than 15° perceived the external rotation of the foot progression angle after TKA. All four patients had an increase in tibial torsion larger than 10°.

conclusionOur study shows that the tibiofemoral synchronization technique less likely affects the tibial torsion after primary TKA.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisOsteoarthritis, KneeFemurHumansKnee JointTibiaComponent rotationTibial torsionTotal knee arthroplasty

Identifiers

PMID33449142
OpenAlexW3119388814

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.