Trial reportJSLS : Journal of the Society of Laparoendoscopic Surgeons
Improving Hemostasis in Sleeve Gastrectomy With Alternative Stapler.
Trial report in JSLS : Journal of the Society of Laparoendoscopic Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Effect of cyanoacrylate-based glue on postoperative leak and bleeding after pancreatectomy and sleeve gastrectomy: a systematic review and meta-analysis.Langenbeck's archives of surgery · 2026Pooled it
- Prospective Randomized Comparison of Linear Endostaplers During Laparoscopic Sleeve Gastrectomy.Obesity surgery · 2022Trial
- Evaluation of the AEON Powered Stapler System in Primary Sleeve Gastrectomy: Results of a Prospective Clinical Trial.Journal of metabolic and bariatric surgery · 2026Article
- The validity of the AEON™ stapler in gastrointestinal surgery: early clinical experience and translational rationale.Frontiers in oncology · 2026Review
- RESULTS OF MECHANIC VERSUS MOTORIZED STAPLER USED IN GASTRIC SURGERY: PROSPECTIVE STUDY.Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery · 2024Article
- Do all roads lead to Rome? A retrospective analysis on surgical technique in sleeve gastrectomy.Surgical endoscopy · 2023Article
- Staple line reinforcement with nebulized cyanoacrylate glue in laparoscopic sleeve gastrectomy: A propensity score-matched study.Open medicine (Warsaw, Poland) · 2022Article
- Comparative Analysis of Hemostasis and Staple-Line Integrity between Medtronic Tri-StapleJSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
- Implementation of a Safe Cost Reduction Strategy for Laparoscopic Sleeve Gastrectomy.JSLS : Journal of the Society of Laparoendoscopic SurgeonsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundStaple line bleeding can be a major intra-operative complication during laparoscopic sleeve gastrectomy, requiring reinforcing interventions that may diminish the integrity of the staple line and put patients at risk for postoperative hemorrhage or leak. To improve outcomes associated with surgery, surgeons may benefit from an alternative stapler that produces a drier staple line and requires less staple line manipulation.
methodsSixty consecutive laparoscopic sleeve gastrectomy procedures were performed by three surgeons; 30 sleeves using the AEON™ Endostapler on THICK MODE and 30 using the Echelon Flex™ Powered Stapler with pulse technique. Stapler performance was measured by incidence and degree of staple line bleeding. Images of the first firing and fundus were taken with the laparoscope 10 seconds after the final firing. Images were evaluated by a third-party blinded evaluator and given a "bleeding score," a qualitative measure of intra-operative staple-line bleeding (1 = no bleeding to 5 = profuse bleeding).
resultsThe AEON™ Endostapler demonstrated a lower mean (± standard error) "bleeding score" versus the Echelon Flex™ (2.1 ± 0.1 vs. 2.6 ± 0.1; p = 0.01). The AEON™ Endostapler had 15 cases (50%) with no bleeding at the fundus; the Echelon Flex™ had 7 cases (23%) with no bleeding at the fundus. The AEON™ Endostapler had 0 cases (0%) with profuse bleeding; the Echelon Flex™ had 2 cases (7%) with profuse bleeding.
conclusionThe AEON™ Endostapler is a significantly drier alternative to the Echelon Flex™ Powered Stapler, producing a much drier staple line and decreasing the need for other bleeding control methods.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.