Evidence map›Paper›PMID 33447003›Full record

Trial reportJSLS : Journal of the Society of Laparoendoscopic Surgeons

Improving Hemostasis in Sleeve Gastrectomy With Alternative Stapler.

James G Redmann, Thomas E Lavin, Matthew S French, Toby D Broussard, Maxime Lapointe-Gagner

Open access · hybridAbstract readMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in JSLS : Journal of the Society of Laparoendoscopic Surgeons. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Review
  5. RESULTS OF MECHANIC VERSUS MOTORIZED STAPLER USED IN GASTRIC SURGERY: PROSPECTIVE STUDY.Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Implementation of a Safe Cost Reduction Strategy for Laparoscopic Sleeve Gastrectomy.JSLS : Journal of the Society of Laparoendoscopic Surgeons
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

James G RedmannSurgical Specialists of Louisiana, Metairie, LA.
Thomas E LavinSurgical Specialists of Louisiana, Metairie, LA.
Matthew S FrenchSurgical Specialists of Louisiana, Metairie, LA.
Toby D BroussardWeight Wise Bariatric Program, Edmond, OK.
Maxime Lapointe-GagnerDepartment of Experimental Surgery, McGill University, Montreal, QC, Canada.
McGill University · CAWashington Center for Weight Management and Research · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStaple line bleeding can be a major intra-operative complication during laparoscopic sleeve gastrectomy, requiring reinforcing interventions that may diminish the integrity of the staple line and put patients at risk for postoperative hemorrhage or leak. To improve outcomes associated with surgery, surgeons may benefit from an alternative stapler that produces a drier staple line and requires less staple line manipulation.

methodsSixty consecutive laparoscopic sleeve gastrectomy procedures were performed by three surgeons; 30 sleeves using the AEON™ Endostapler on THICK MODE and 30 using the Echelon Flex™ Powered Stapler with pulse technique. Stapler performance was measured by incidence and degree of staple line bleeding. Images of the first firing and fundus were taken with the laparoscope 10 seconds after the final firing. Images were evaluated by a third-party blinded evaluator and given a "bleeding score," a qualitative measure of intra-operative staple-line bleeding (1 = no bleeding to 5 = profuse bleeding).

resultsThe AEON™ Endostapler demonstrated a lower mean (± standard error) "bleeding score" versus the Echelon Flex™ (2.1 ± 0.1 vs. 2.6 ± 0.1; p = 0.01). The AEON™ Endostapler had 15 cases (50%) with no bleeding at the fundus; the Echelon Flex™ had 7 cases (23%) with no bleeding at the fundus. The AEON™ Endostapler had 0 cases (0%) with profuse bleeding; the Echelon Flex™ had 2 cases (7%) with profuse bleeding.

conclusionThe AEON™ Endostapler is a significantly drier alternative to the Echelon Flex™ Powered Stapler, producing a much drier staple line and decreasing the need for other bleeding control methods.

Indexed as

GastrectomyLaparoscopySurgical StaplingFemaleHemostasis, SurgicalHumansMaleMiddle AgedComplicationsHemostasisSleeve gastrectomySurgical stapler

Identifiers

PMID33447003
PMCPMC7791089
OpenAlexW3125865028

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.