Evidence map›Paper›PMID 33445532›Full record

ArticleSensors (Basel, Switzerland)2021

A Flexible Pressure Sensor with Ink Printed Porous Graphene for Continuous Cardiovascular Status Monitoring.

Yuxin Peng, Jingzhi Zhou, Xian Song, Kai Pang, Akram Samy, Zengming Hao, Jian Wang

Abstract readLetter
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Review
  3. Review
  4. Review
  5. Graphene-based cardiac sensors and actuators.Frontiers in bioengineering and biotechnology · 2023
    Review
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuxin PengDepartment of Sports Science, Zhejiang University, Hangzhou 310058, China.ORCID 0000-0002-8121-4814
Jingzhi ZhouDepartment of Sports Science, Zhejiang University, Hangzhou 310058, China.
Xian SongDepartment of Sports Science, Zhejiang University, Hangzhou 310058, China.
Kai PangDepartment of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China.
Akram SamyDepartment of Civil Engineering and Architecture, Zhejiang University, Hangzhou 310058, China.ORCID 0000-0001-6930-342X
Zengming HaoDepartment of Sports Science, Zhejiang University, Hangzhou 310058, China.
Jian WangDepartment of Sports Science, Zhejiang University, Hangzhou 310058, China.

Funding

2018 Qianjiang Talent Program of Zhejiang Province QJC1802009Fundamental Research Funds for the Central Universities 2020XZA206MOE (Ministry of Education in China) Project of Humanities and Social Sciences 19YJCZH126National Key Research and Development Program of China 2018YFF0300501Natural Science Foundation of Zhejiang Province LQ19C100002the "Double First-Class" Construction Fund of Zhejiang University N/A
6 · The paper itself

Abstract

Flexible electronics with continuous monitoring ability a extensively preferred in various medical applications. In this work, a flexible pressure sensor based on porous graphene (PG) is proposed for continuous cardiovascular status monitoring. The whole sensor is fabricated in situ by ink printing technology, which grants it the potential for large-scale manufacture. Moreover, to enhance its long-term usage ability, a polyethylene terephthalate/polyethylene vinylacetate (PET/EVA)-laminated film is employed to protect the sensor from unexpected shear forces on the skin surface. The sensor exhibits great sensitivity (53.99/MPa), high resolution (less than 0.3 kPa), wide detecting range (0.3 kPa to 1 MPa), desirable robustness, and excellent repeatability (1000 cycles). With the assistance of the proposed pressure sensor, vital cardiovascular conditions can be accurately monitored, including heart rate, respiration rate, pulse wave velocity, and blood pressure. Compared to other sensors based on self-supporting 2D materials, this sensor can endure more complex environments and has enormous application potential for the medical community.

Indexed as

Cardiovascular SystemWearable Electronic DevicesAdultBlood PressureEquipment DesignGraphiteHeart RateHumansInkMonitoring, PhysiologicPolyethylene TerephthalatesPolyvinylsPorosityPulse Wave AnalysisRespirationSkinethylenevinylacetate copolymerGraphitePolyethylene TerephthalatesPolyvinylsblood pressure estimationflexible pressure sensorporous grapheneshear force elimination

Identifiers

PMID33445532
PMCPMC7828094

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.