ArticleJournal of applied clinical medical physics2021
Automatic couch position calculation using eclipse scripting for external beam radiotherapy.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Quality Management for Radiation Oncology In-House Software Products.Bioengineering (Basel, Switzerland) · 2025Article
- Machine learning-based treatment couch parameter prediction in support of surface guided radiation therapy.Technical innovations & patient support in radiation oncology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe treatment couch position of a patient in external beam radiation therapy (EBRT) is usually acquired during initial treatment setup. This procedure has shown potential failure modes leading to near misses and adverse events in radiation treatment. This study aims to develop a method to automatically determine the couch position before setting up a patient for initial treatment.
methodsThe Qfix couch-tops (kVue and DoseMax) have embedded reference marks (BBs) indicating its index levels and couch centerline. With the ESAPI, a C# script was programmed to automatically find the couch-top and embedded BBs in the planning CT and derive the treatment couch position according to treatment isocenter of a plan. Couch positions of EBRT plans with the kVue couch-top and SBRT plans using the DoseMax were calculated using the script. The calculation was evaluated by comparing calculated positions with couch coordinates captured during the initial treatment setup after image guidance. The calculations were further compared with daily treatment couch positions post image-guided adjustment for each treatment fraction.
resultsFor plans using the kVue couch-top for various treatment sites, the median (5-95 percentiles) differences between calculated and captured couch positions were 0.1 (-0.2 - 0.9), 0.5 (-1.1-2.0), 0.10 (-1.3-1.3) cm in the vertical, longitudinal, and lateral direction respectively. For the DoseMax couch-top, the median differences were 0.1 (-0.2-0.7), 0.2 (-0.3-1.1), and 0.2 (-0.7-0.9) cm in respective direction. The calculated positions were within 1 and 2 cm from the mean fraction positions for 95% patients on DoseMax and kVue couch-top respectively.
conclusionsA method that automatically and accurately calculates treatment couch position from simulation CT was implemented in Varian Eclipse for Qfix couch-tops. This technique increases the efficiency of patient setup and enhances patient safety by reducing the risks of positioning errors.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.