Evidence map›Paper›PMID 33440056›Full record

ArticleJournal of applied clinical medical physics2021

Vendor-independent skin dose mapping application for interventional radiology and cardiology.

Marko Krajinović, Nikola Kržanović, Olivera Ciraj-Bjelac

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Marko KrajinovićSchool of Electrical Engineering, University of Belgrade, Belgrade, Serbia.
Nikola KržanovićSchool of Electrical Engineering, University of Belgrade, Belgrade, Serbia.
Olivera Ciraj-BjelacSchool of Electrical Engineering, University of Belgrade, Belgrade, Serbia.
University of Belgrade · RS

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe purpose of this paper is to present and validate an originally developed application SkinCare used for skin dose mapping in interventional procedures, which are associated with relatively high radiation doses to the patient's skin and possible skin reactions.

methodsSkinCare is an application tool for generating skin dose maps following interventional radiology and cardiology procedures using the realistic 3D patient models. Skin dose is calculated using data from Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Reports (RDSRs). SkinCare validation was performed by using the data from the Siemens Artis Zee Biplane fluoroscopy system and conducting "Acceptance and quality control protocols for skin dose calculating software solutions in interventional cardiology" developed and tested in the frame of the VERIDIC project. XR-RV3 Gafchromic films were used as dosimeters to compare peak skin doses (PSDs) and dose maps obtained through measurements and calculations. DICOM RDSRs from four fluoroscopy systems of different vendors (Canon, GE, Philips, and Siemens) were used for the development of the SkinCare and for the comparison of skin dose maps generated using SkinCare to skin dose maps generated by different commercial software tools (Dose Tracking System (DTS) from Canon, RadimetricsTM from Bayer and RDM from MEDSQUARE). The same RDSRs generated during a cardiology clinical procedure (percutaneous coronary intervention-PCI) were used for comparison.

resultsValidation performed using VERIDIC's protocols for skin dose calculation software showed that PSD calculated by SkinCare is within 17% and 16% accuracy compared to measurements using XR-RV3 Gafchromic films for fundamental irradiation setups and simplified clinical procedures, respectively. Good visual agreement between dose maps generated by SkinCare and DTS, Radimetrics

conclusionsSkinCare is proved to be very convenient solution that can be used for monitoring delivered dose following interventional procedures.

Indexed as

CardiologyPercutaneous Coronary InterventionFluoroscopyHumansRadiation DosageRadiography, InterventionalRadiology, InterventionalSkinDICOM RDSRinterventional proceduresSkinCare applicationskin dose assessmentsoftwareXR-RV3 GafChromic films

Identifiers

PMID33440056
PMCPMC7882120
OpenAlexW3121068760

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.