ArticleAnnals of translational medicine2020
Feasibility of microscope-integrated swept-source optical coherence tomography in canaloplasty.
Article in Annals of translational medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSeveral researchers have used commercial microscope-integrated optical coherence tomography (OCT) systems in glaucoma surgery, including
methodsSixteen porcine eyes were used to simulate canaloplasty. The critical surgical steps were monitored using a prototype microscope-integrated OCT system with a 1,310 nm light source and a high axial scan rate of 100 kHz. The images from swept-source OCT and three-dimensional images from the microscope were projected simultaneously onto a liquid crystal display three-dimensional monitor (LMD-4251TD, Sony, Japan). The changes in the collector vessel (aqueous drainage structure in the porcine eye, similar to Schlemm's canal in humans) were measured using Image J software. Histological sections stained with hematoxylin and eosin were used to assess surgical efficacy.
resultsHigh-resolution real-time images of the anterior segment were acquired during canaloplasty using the microscope-integrated OCT system. With the real-time OCT images, the position of the collector vessel was identified and the scleral flap could be created at the ideal location. The expansion of the collector vessel after viscoelastic injection was also visualized in real time. Compared with baseline, there was a significant increase in the cross-sectional area (from 14,502.98±9,242.55 to 59,499.04±20,506.41 µm
conclusionsUsing the microscope-integrated OCT system, real-time images of the anterior segment were successfully acquired during the operation. The microscope-integrated OCT system might be useful in future anti-glaucoma surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials