Silicone Oil Decreases Biofilm Formation in a Capacitance-Based Automatic Urine Measurement System.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 3 citations in OpenAlex.
- Development of a urinometer for automatic measurement of urine flow in catheterized patients.PloS one · 2023Article
- Systematic Review of Automated Diuresis Measurement in Critically Ill Patients.Medical devices (Auckland, N.Z.) · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Capacitance-based automatic urine measurement is a validated technique already implemented in clinical practice. However, albuminuria and free hemoglobinuria cause progressive biofilm buildup on the capacitance sensors of the urinometers. The aim of this experimental study is to investigate the influence of albumin and free hemoglobin on the capacitance signal of an automatic urinometer with and without the addition of silicone oil. A solution of Ringer's acetate mixed with either albumin or free hemoglobin was run through an automatic urinometer containing either a water-soluble capsule with silicone oil or not. In total, around 500 capacitance measurements were retrieved from the albumin and free hemoglobin group, respectively. The mean increase in capacitance in the albumin 3 g/L group was 257 ± 100 pF without and 105 ± 30 pF with silicone oil, respectively, during 24 h. After ten hours of recording, differences between the two albumin groups reached statistical significance. For the free hemoglobin groups (0.01 g/L), the mean increase in capacitance was 190 ± 170 pF with silicone oil, and 324 ± 80 pF without, with a significant difference between the groups after 20 h and onwards. Coating of the capacitance measurement membrane of the automatic urinometer by albumin or free hemoglobin was significantly decreased by silicone oil, prolonging the functionality of the device.