Evidence map›Paper›PMID 33430780›Full record

ArticleBMC medical imaging2021

Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP.

Felix Christian Hasse, Buket Selmi, Hamed Albusaidi, Theresa Mokry, Philipp Mayer, Christian Rupp, Hans-Ulrich Kauczor, Tim Frederik Weber

Open access · goldAbstract read
In one paragraph

Article in BMC medical imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.8field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Felix Christian HasseDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany. Felix.Hasse@med.uni-heidelberg.de.ORCID 0000-0002-0438-8247
Buket SelmiDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Hamed AlbusaidiDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Theresa MokryDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Philipp MayerDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Christian RuppDepartment of Gastroenterology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany.
Hans-Ulrich KauczorDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Tim Frederik WeberDiagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
Heidelberg University · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDespite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP.

methodsThis is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis.

resultsOverall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s).

conclusionsNon-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.

Indexed as

AdultAgedArtifactsBile DuctsCholangiopancreatography, Magnetic ResonanceFemaleHumansImaging, Three-DimensionalMaleMiddle AgedObserver VariationPancreasRespirationRetrospective StudiesYoung AdultBiliary tractCholangiopancreatographyMagnetic resonancePancreas

Identifiers

PMID33430780
PMCPMC7802244
OpenAlexW3119593562

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.