Physician-Friendly Tool Center Point Calibration Method for Robot-Assisted Puncture Surgery.

Leifeng Zhang, Changle Li, Yilun Fan, Xuehe Zhang, Jie Zhao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Leifeng ZhangState Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.
Changle LiState Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.
Yilun FanState Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.
Xuehe ZhangState Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.ORCID 0000-0001-8138-2802
Jie ZhaoState Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin 150001, China.

Funding

Major scientific and technological innovation projects in Shandong Province 2019JZZY010430National Key Research and Development Program of China 2019YFB1311303Natural Science Foundation of China U1713202
6 · The paper itself

Abstract

After each robot end tool replacement, tool center point (TCP) calibration must be performed to achieve precise control of the end tool. This process is also essential for robot-assisted puncture surgery. The purpose of this article is to solve the problems of poor accuracy stability and strong operational dependence in traditional TCP calibration methods and to propose a TCP calibration method that is more suitable for a physician. This paper designs a special binocular vision system and proposes a vision-based TCP calibration algorithm that simultaneously identifies tool center point position (TCPP) and tool center point frame (TCPF). An accuracy test experiment proves that the designed special binocular system has a positioning accuracy of ±0.05 mm. Experimental research shows that the magnitude of the robot configuration set is a key factor affecting the accuracy of TCPP. Accuracy of TCPF is not sensitive to the robot configuration set. Comparison experiments show that the proposed TCP calibration method reduces the time consumption by 82%, improves the accuracy of TCPP by 65% and improves the accuracy of TCPF by 52% compared to the traditional method. Therefore, the method proposed in this article has higher accuracy, better stability, less time consumption and less dependence on the operations than traditional methods, which has a positive effect on the clinical application of high-precision robot-assisted puncture surgery.

Indexed as

PhysiciansRoboticsRobotic Surgical ProceduresCalibrationHumansPuncturesbinocular visionpuncture surgeryrobot TCP calibration

Identifiers

PMID33430365
PMCPMC7825783

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.