Evidence map›Paper›PMID 33428608›Full record

Trial reportMedical science monitor : international medical journal of experimental and clinical research2021

Lightwand-Guided Insertion of Flexible Reinforced Laryngeal Mask Airway: Comparison with Standard Digital Manipulation Insertion.

Dae Hee Kim, Yun Jeong Chae, Sang Kee Min, Eun Ji Ha, Ji Young Yoo

Open access · hybridAbstract readComparative StudyRandomized Controlled Trial
In one paragraph

Trial report in Medical science monitor : international medical journal of experimental and clinical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
0.8field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 3 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Dae Hee KimDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea.
Yun Jeong ChaeDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea.
Sang Kee MinDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea.
Eun Ji HaDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea.
Ji Young YooDepartment of Anesthesiology and Pain Medicine, Ajou University School of Medicine, Suwon, Gyeonggi, South Korea.
Ajou University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND The flexibility of the long flexometallic tube makes insertion of the flexible reinforced laryngeal mask airway (f-LMA) difficult. We compared the usefulness of rigid lightwand-guided f-LMA insertion with standard digital manipulation. MATERIAL AND METHODS Fifty-four patients (aged 19-70 years) were randomly divided into a control group (digital manipulation technique) or the lightwand group (lightwand-guided insertion technique). The insertion profiles, oropharyngeal leak pressure (OLP), peak inspiratory pressure (PIP), expiratory tidal volume, and ventilatory score were measured in patients with neutral, extension, rotation, flexion, and re-neutral head-neck positions in turn. RESULTS The success rate and ease of insertion did not differ between groups, but the insertion time was longer in the lightwand group. The fiberoptic laryngeal view was significantly better in the lightwand group than in the control group. However, the OLP, PIP, expiratory tidal volume, and ventilatory scores were not significantly different between groups according to head-neck positions. The extension posture was associated with a significant negative effect on ventilation, but ventilation returned to initial levels with the other postures. CONCLUSIONS Lightwand-guided f-LMA insertion showed a better fiberoptic laryngeal view than standard digital manipulation, but no improvement in the ventilatory state was observed due to position. Therefore, lightwand-guided insertion could facilitate correct placement of the f-LMA, but it has limited clinical usefulness.

Indexed as

AdultAgedFemaleFiber Optic TechnologyHumansIntubation, IntratrachealLarynxMaleMiddle AgedPatient PositioningPulmonary VentilationTidal Volume

Identifiers

PMID33428608
PMCPMC7812698
OpenAlexW3099945219

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.