The impact of data selection and fitting on SAR estimation for magnetic nanoparticle heating.

Hattie L Ring, Anirudh Sharma, Robert Ivkov, John C Bischof

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Hattie L RingCenter for Magnetic Resonance Imaging, University of Minnesota, Minneapolis, MN, USA.ORCID 0000-0001-5779-2561
Anirudh SharmaDepartment of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA.
Robert IvkovDepartment of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
John C BischofDepartment of Mechanical Engineering, University of Minnesota, Minneapolis, MN, USA.

Funding

Organ banking for transplant—kidney cryopreservation by vitrification and novel nanowarming technologyR01DK117425 · NIDDK · UNIVERSITY OF MINNESOTA · PI JOHN C BISCHOF, Erik Brian Finger · 2018 to 2026
$4.9M
Translational Application of Magnetic Hyperthermia Therapy with Adjuvant Therapies for GlioblastomaR01CA247290 · NCI · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI HADJIPANAYIS, CONSTANTINOS GEORGE, IVKOV, ROBERT · 2020 to 2024
$3.5M
Enhancing Liver Cancer Treatment With Image-Guided Magnetic HyperthermiaR01CA194574 · NCI · JOHNS HOPKINS UNIVERSITY · PI IVKOV, ROBERT · 2015 to 2019
$3.2M
Breakthrough Tissue and Organ Preservation and Transplantation Using Scaled-Up Nanowarming TechnologyR01HL135046 · NHLBI · UNIVERSITY OF MINNESOTA · PI BISCHOF, JOHN C, FINGER, ERIK BRIAN · 2017 to 2020
$2.6M
NCI NIH HHS R01 CA194574NCI NIH HHS R01 CA247290NHLBI NIH HHS R01 HL135046NIDDK NIH HHS R01 DK117425
6 · The paper itself

Abstract

backgroundMagnetic fluid heating has great potential in the fields of thermal medicine and cryopreservation. However, variations among experimental parameters, analysis methods and experimental uncertainty make quantitative comparisons of results among laboratories difficult. Herein, we focus on the impact of calculating the specific absorption rate (SAR) using Time-Rise and Box-Lucas fitting. Time-Rise assumes adiabatic conditions, which is experimentally unachievable, but can be reasonably assumed (quasi-adiabatic) only for specific and limited evaluation times when heat loss is negligible compared to measured heating rate. Box-Lucas, on the other hand, accounts for heat losses but requires longer heating.

methodsThrough retrospective analysis of data obtained from two laboratories, we demonstrate measurement time is a critical parameter to consider when calculating SAR. Volumetric SAR were calculated using the two methods and compared across multiple iron-oxide nanoparticles.

resultsWe observed the lowest volumetric SAR variation from both fitting methods between 1-10 W/mL, indicating an ideal SAR range for heating measurements. Furthermore, our analysis demonstrates that poorly chosen fitting method can generate reproducible but inaccurate SAR.

conclusionWe provide recommendations to select measurement time for data analysis with either Modified Time-Rise or Box-Lucas method, and suggestions to enhance experimental precision and accuracy when conducting heating experiments.

Indexed as

Magnetite NanoparticlesHot TemperatureMagneticsRetrospective StudiesMagnetite Nanoparticlesdata analysismagnetic fluid hyperthermiaMagnetic iron oxide nanoparticlesnanowarmingspecific absorption rate calculation

Identifiers

PMID33426988
PMCPMC7888243

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.