Evidence map›Paper›PMID 33426704›Full record

ArticleMedical physics2021

Semiempirical, parameterized spectrum estimation for x-ray computed tomography.

Paul FitzGerald, Stephen Araujo, Mingye Wu, Bruno De Man

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. XCIST-an open access x-ray/CT simulation toolkit.Physics in medicine and biology · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Paul FitzGeraldGE Research, Niskayuna, NY, 12309, USA.
Stephen AraujoGE Research, Niskayuna, NY, 12309, USA.
Mingye WuGE Research, Niskayuna, NY, 12309, USA.
Bruno De ManGE Research, Niskayuna, NY, 12309, USA.

Funding

Open-access X-ray and CT simulation toolkit for research in cancer imaging and dosimetryU01CA231860 · NCI · GENERAL ELECTRIC GLOBAL RESEARCH CTR · PI DE MAN, BRUNO · 2019 to 2021
$1.5M
National Cancer Institute of the National Institutes of Health U01CA231860NCI NIH HHS U01 CA231860
6 · The paper itself

Abstract

purposeTo develop a tool to produce accurate, well-validated x-ray spectra for standalone use or for use in an open-access x-ray/CT simulation tool. Spectrum models will be developed for tube voltages in the range of 80 kVp through 140 kVp and for anode takeoff angles in the range of 5° to 9°.

methodsSpectra were initialized based on physics models, then refined using empirical measurements, as follows. A new spectrum-parameterization method was developed, including 13 spline knots to represent the bremsstrahlung component and 4 values to represent characteristic lines. Initial spectra at 80, 100, 120, and 140 kVp and at takeoff angles from 5° to 9° were produced using physics-based spectrum estimation tools XSPECT and SpekPy. Empirical experiments were systematically designed with careful selection of attenuator materials and thicknesses, and by reducing measurement contamination from scatter to <1%. Measurements were made on a 64-row CT scanner using the scanner's detector and using multiple layers of polymethylmethacrylate (PMMA), aluminum, titanium, tin, and neodymium. Measurements were made at 80, 100, 120, and 140 kVp and covering the entire 64-row detector (takeoff angles from 5° to 9°); a total of 6,144 unique measurements were made. After accounting for the detector's energy response, parameterized representations of the initial spectra were refined for best agreement with measurements using two proposed optimization schemes: based on modulation and based on gradient descent. X-ray transmission errors were computed for measurements vs calculations using the nonoptimized and optimized spectra. Half-value, tenth-value, and hundredth-value layers for PMMA, Al, and Ti were calculated.

resultsSpectra before and after parameterization were in excellent agreement (e.g., R

conclusionThe resulting well-validated spectra are appropriate for use in the open-access x-ray/CT simulator under development, the x-ray-based Cancer Imaging Toolkit (XCIST), or for standalone use. These spectra can be readily interpolated to produce spectra at arbitrary kVps over the range of 80 to 140 kVp and arbitrary takeoff angles over the range of 5° to 9°. Furthermore, interpolated spectra over these ranges can be obtained by applying the standalone Matlab function available at https://github.com/xcist/documentation/blob/master/XCISTspectrum.m.

Indexed as

Models, TheoreticalTomography, X-Ray ComputedComputer SimulationTomography Scanners, X-Ray ComputedX-Rayssimulationspectrum modelx-ray

Identifiers

PMID33426704
PMCPMC8140990

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.