Evidence map›Paper›PMID 33426606›Full record

SynthesisArchives of orthopaedic and trauma surgery2022

Outcomes and complications of the INFIX technique for unstable pelvic ring injuries with high-velocity trauma: a systematic review and meta-analysis.

Sandeep Patel, Sameer Aggarwal, Karan Jindal, Vishal Kumar, Siddhartha Sharma

Abstract readMeta-AnalysisSystematic Review
PubMed Publisher
In one paragraph

Synthesis in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 2 pooled it
4.0field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 2 syntheses or guidelines pooled it, 23 citations in OpenAlex.

  1. Iatrogenic nerve injury following pelvic ring injury: a network meta-analysis.International journal of surgery (London, England) · 2025
    Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. [Modified anterior subcutaneous internal fixation versus open reduction and plate fixation in treatment of pubic symphysis diastasis].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2026
    Article
  8. Article
  9. Article
  10. Outcome of pelvic ring injuries.Archives of orthopaedic and trauma surgery · 2024
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. [Modified internal fixator combined with sacroiliac screws in treatment of Tile C1.3 pelvic fracture].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2022
    Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Sandeep PatelPost Graduate Institute of Medical Education and Research, Chandigarh, India.
Sameer AggarwalPost Graduate Institute of Medical Education and Research, Chandigarh, India.
Karan JindalPost Graduate Institute of Medical Education and Research, Chandigarh, India. karan.121@hotmail.com.ORCID http://orcid.org/0000-0003-2461-6005
Vishal KumarPost Graduate Institute of Medical Education and Research, Chandigarh, India.
Siddhartha SharmaPost Graduate Institute of Medical Education and Research, Chandigarh, India.
Post Graduate Institute of Medical Education and Research · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe pelvic INFIX technique has been proposed as a useful alternative to symphyseal plating for management of unstable pelvic ring injuries. The minimally invasive nature of the procedure, shorter operative time and less perioperative blood loss have been purported as potential advantages. QUESTIONS/PURPOSES: This systematic review and meta-analysis were conducted to determine the outcomes and complications of the INFIX technique for unstable pelvic ring injuries.

methodsA systematic review of literature was performed on the PubMed, EMBASE and Scopus databases. Prospective and retrospective studies in all languages, whether comparative or non-comparative, pertaining to the use of INFIX in pelvic fractures were included. Studies which did not evaluate INFIX, case reports, conference abstracts and those with less than 10 cases were excluded. Cadaveric studies, technique papers and studies that did not describe the prespecified outcome measures were also excluded. Meta-analysis consisted of two different arms: a comparative arm, to compare INFIX to symphyseal plating, and a non-comparative meta-analysis arm, to determine pooled rates of outcomes and complications. Risk of bias was determined by the Methodological Index for Non-Randomised Studies (MINORS) tool.

resultsA total of 22 studies were included in the systematic review, of which 7 were comparative and 15 were non-comparative. 746 patients were included for qualitative analysis and pooled analysis done for 589 patients. The average follow-up of these studies ranged from a minimum of 5.4 months to a maximum of 54 months. Comparative meta-analysis (n = 3 studies) of plating and INFIX showed significantly lesser blood loss (mean difference = 176.46 mL; 95% CI - 207.54 to - 145.38) and shorter operative time (mean difference = 26.43 min, 95% CI - 31.79 to - 21.07) with INFIX, but no significant difference in the overall complication rates (OR 1.59, 95% CI 0.83-3.05) and functional outcome scores (mean difference = - 2.51, 95% CI - 5.73 to 0.71). Pooled analysis showed overall good radiological (mean percentage of excellent to good reduction = 91.4%, 95% CI 0.860-0.969) and functional outcomes (mean Majeed score = 86.48, 95% CI 83.34-89.61) with INFIX. The most common complications were lateral femoral cutaneous nerve (LFCN) injury (overall rate 28%, 95% CI 15.1-41%) and heterotopic ossification (HO) (overall rate 9.4%, 95% CI 5.5-13.3%); rates of other complications were low. Significant heterogeneity was noted in the pooled analysis of blood loss, operative time, functional outcome, HO and LFCN injury. The overall strength of evidence was found to be weak.

conclusionThe INFIX technique can be considered as a viable alternative to symphyseal plating for unstable pelvic ring injuries. It has the advantages of shorter operative times and less blood loss, along with comparable functional outcomes, when compared to plating. Overall, good functional outcomes can be expected. However, well-designed, multi-center randomized controlled trials are needed to conclusively prove the benefit of this technique.

Indexed as

Fractures, BonePelvic BonesFracture Fixation, InternalHumansProspective StudiesRetrospective StudiesComplicationsEfficacyINFIXOutcomes

Identifiers

PMID33426606
OpenAlexW3119941952

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.