ArticleJournal of orthopaedic surgery and research2021
A novel surgical approach and technique and short-term clinical efficacy for the treatment of proximal humerus fractures with the combined use of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation.
Article in Journal of orthopaedic surgery and research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 14 citations in OpenAlex.
- Radiographic outcomes of a standardized versus conventional reduction technique in proximal humerus fractures: a matched cohort study.JSES international · 2026Article
- Imaging-based assessment of fracture stability does not reliably predict outcomes in patients with two-part proximal humeral fractures and may lead to unnecessary surgeries.EFORT open reviews · 2026Review
- Superior outcome with anterolateral approach in treating O'Driscoll type II ulnar coronoid process fractures: a retrospective analysis.American journal of translational research · 2025Article
- Application of Intramedullary Calcar Support Plate and Lateral Locking Plate in Elderly Patients with Neer 3 and 4-Part Fractures of Proximal Humerus Through a Deltoid Splitting Approach.Indian journal of orthopaedics · 2024Article
- Morphology and novel classification of proximal humeral fractures.Frontiers in bioengineering and biotechnology · 2024Article
- Biomechanical evaluation of novel intra- and extramedullary assembly fixation for proximal humerus fractures in the elderly.Frontiers in bioengineering and biotechnology · 2023Article
- Application of a lateral intertubercular sulcus plate in the treatment of proximal humeral fractures: a finite element analysis.BMC surgery · 2022Article
- Anatomical study for the treatment of proximal humeral fracture through the medial approach.Journal of orthopaedic surgery and research · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 6 institutions in 1 country.
Funding
Abstract
background and hypothesisThe typical anterolateral approach is widely used to treat proximal humerus fractures with lateral locking fixation. However, lateral fixation cannot completely avoid medial reduction loss and varus deformity especially in the cases of an unstable medial column. We present a novel medial surgical approach and technique together with a minimally invasive lateral locking plate to fix proximal humerus fractures with an unstable medial column. MATERIALS AND
methodsWe performed an anatomical study and reported 8 cases of proximal humerus fractures with unstable medial columns treated with plate fixation through a minimally invasive anterolateral approach and medial approach. All surgeries were performed by the same single surgeon. Patients were followed clinically and radiographically at 1, 3, 6, and 12 months postoperatively.
resultsThere was a safe region located at the medial part of the proximal humerus just beneath the articular surface. An anatomical medial locking proximal humerus plate could be placed in the medial column and did not affect the axillary nerve, blood supply of the humeral head, or stability of the shoulder joint. Successful fracture healing was achieved in all 8 cases. The function and range of motion of the shoulder joint were satisfactory 24 months postoperatively, with an average Constant score (CS) of 82.8. No reduction loss (≥ 10° in any direction), screw cutout, nonunion, or deep infection occurred.
conclusionsThe combined application of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation is effective in maintaining operative reduction and preventing varus collapse and implant failure in proximal humerus fractures with an unstable medial column.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.