Evidence map›Paper›PMID 33417430›Full record

ArticleAnalytical chemistry2021

Improving the Accuracy of Pdot-Based Continuous Glucose Monitoring by Using External Ratiometric Calibration.

Kai Sun, Siyang Liu, Jing Liu, Zhaoyang Ding, Yifei Jiang, Jicheng Zhang, Haobin Chen, Jiangbo Yu, Changfeng Wu, Daniel T Chiu

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 2 countries.

Kai SunDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.ORCID 0000-0002-1109-8934
Siyang LiuDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.
Jing LiuDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.
Zhaoyang DingDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.ORCID 0000-0003-4657-992X
Yifei JiangDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.ORCID 0000-0003-1818-4541
Jicheng ZhangDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.
Haobin ChenDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.ORCID 0000-0003-3111-9824
Jiangbo YuDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.
Changfeng WuDepartment of Biomedical Engineering, Southern University of Science and Technology, Shenzhen, Guangdong 518055, China.ORCID 0000-0001-6797-9784
Daniel T ChiuDepartment of Chemistry and Bioengineering, University of Washington, Seattle, Washington 98195, United States.ORCID 0000-0003-2964-9578
University of Washington · USSouthern University of Science and Technology · CN

Funding

High-precision mapping of the spatial organization of synaptic-vesicle membrane proteinsR01MH113333 · NIMH · UNIVERSITY OF WASHINGTON · PI CHIU, DANIEL T · 2017 to 2021
$1.9M
NIMH NIH HHS R01 MH113333
6 · The paper itself

Abstract

Continuous glucose monitoring (CGM) allows type I and II diabetes patients to track changes in their glucose levels, allowing detection of impending hypoglycemia or hyperglycemia. Polymer dots (Pdots) are candidates for use in implanted CGM systems due to their exceptional brightness, photostability, sensitivity, and biocompatibility. However, Pdot glucose transducers are oxygen-dependent, and changes in tissue oxygen levels affect their measurement accuracy. Here, we describe an external ratiometric calibration method that corrects for changes in tissue oxygen levels to improve measurement accuracy. This method uses the ratio of oxygen concentrations inside and outside the Pdot glucose transducer as an indicator of glucose concentration to correct for signal deviations caused by tissue oxygen fluctuations. A second oxygen-sensitive Pdot that is not conjugated with glucose oxidase is used to measure the oxygen concentration outside the Pdot glucose transducer. We describe the theoretical basis for this approach and demonstrate its effectiveness experimentally in a subcutaneous mouse implant model. This external ratiometric system achieves higher accuracy glucose measurements than previous Pdot-based CGM systems and comparable accuracy to current commercial CGM systems, demonstrating the utility of the external ratiometric calibration strategy.

Indexed as

CalibrationTransducersAnimalsBlood GlucoseFemaleFluorescent DyesMiceMice, Inbred BALB CMonitoring, PhysiologicPolymersBlood GlucoseFluorescent DyesPolymers

Identifiers

PMID33417430
PMCPMC10226373
OpenAlexW3119269019

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.