Evidence map›Paper›PMID 33415530›Full record

ArticleEnvironmental monitoring and assessment2021

Distribution and comparison of bacterial communities in HVAC systems of two university buildings: Implications for indoor air quality and public health.

Timothy Sibanda, Ramganesh Selvarajan, Henry Jo Ogola, Chinedu Christopher Obieze, Memory Tekere

Open access · bronzeAbstract read
In one paragraph

Article in Environmental monitoring and assessment, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 4 countries.

Timothy SibandaDepartment of Biological Sciences, University of Namibia, Mandume Ndemufayo Ave, Pionierspark, Windhoek, Namibia. timsibanda@gmail.com.ORCID http://orcid.org/0000-0002-6864-3796
Ramganesh SelvarajanDepartment of Environmental Sciences, College of Agricultural and Environmental Sciences, UNISA, Johannesburg, South Africa.ORCID https://orcid.org/0000-0002-7104-3599
Henry Jo OgolaDepartment of Environmental Sciences, College of Agricultural and Environmental Sciences, UNISA, Johannesburg, South Africa.ORCID https://orcid.org/0000-0003-1603-6430
Chinedu Christopher ObiezeDepartment of Microbiology, University of Port Harcourt, Port Harcourt, Nigeria.ORCID https://orcid.org/0000-0002-1381-0948
Memory TekereDepartment of Environmental Sciences, College of Agricultural and Environmental Sciences, UNISA, Johannesburg, South Africa.ORCID https://orcid.org/0000-0002-0606-7826
University of South Africa · ZAUniversity of Namibia · NAUniversity of Port Harcourt · NG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The installation of HVAC systems in building is meant to enhance indoor air quality as well as increase comfort to occupants. However, HVAC systems have also become a vehicle of contamination of indoor air with potentially pathogenic microorganisms. DNA was extracted from ten HVAC filter dust samples collected from two buildings and subjected to high throughput sequencing analysis to determine the bacterial community structure. Further, the Phylogenetic Investigation of Communities by Reconstruction of Unobserved States (PICRUSt2) software was used to predict the potential functional capabilities of the bacterial communities. Sequencing analysis led to the identification of five major bacterial phyla, including Proteobacteria, Cyanobacteria, Actinobacteria, Firmicutes and Bacteroidetes. At genus level, Mycobacterium, Bacillus, Cupriavidus, Hyphomicrobium and Mesorhizobium were the most dominant. With the exception of the later two bacterial genera, the first three are potential pathogens whose presence in HVAC systems poses a significant public health risk, especially among immunocompromised individuals. Nine pathways associated with antibiotics resistance and bacterial pathogenicity were identified, including polymyxin resistance and peptidoglycan biosynthesis pathways. Further, investigation of the relationship between the detected bacterial meta-communities and predicted potential virulence factors (antibiotic resistance and pathogenic genes) led to the detection of 350 positive associations among 43 core bacteria, 2 pathogenic genes (sitA and uidA) and 14 resistance genes. Overall, the heterogeneous nature of microorganisms found in HVAC systems observed in this study shows that HVAC systems are the origin of airborne infections in indoor environments, and must be periodically cleaned and disinfected to avoid the build-up of pathogens, and the subsequent exposure of human occupants of these pathogens.

Indexed as

Air Pollution, IndoorAir ConditioningAir MicrobiologyBacteriaEnvironmental MonitoringHumansPhylogenyPublic HealthUniversitiesVentilationBioaerosolsHVAC systemsIndoor airPICRUSt2Public healthSequencing analysis

Identifiers

PMID33415530
PMCPMC7790485
OpenAlexW3119123689

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials