Evidence map›Paper›PMID 33412004›Full record

ArticleAnalytical chemistry2021

Mass Spectrometry Spatial-Omics on a Single Conductive Slide.

Stephanie T P Mezger, Alma M A Mingels, Otto Bekers, Ron M A Heeren, Berta Cillero-Pastor

Abstract read
In one paragraph

Article in Analytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

29 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. MALDI spatial proteomics: a mini review of approaches and techniques.Analytical methods : advancing methods and applications · 2026
    Review
  5. Structure Analysis of Gangliosides: Mass Spectrometry Imaging.Methods in molecular biology (Clifton, N.J.) · 2026
    Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Spatial MS multiomics on clinical prostate cancer tissues.Analytical and bioanalytical chemistry · 2024
    Article
  16. Quantitative mass spectrometry imaging: therapeutics & biomolecules.Chemical communications (Cambridge, England) · 2024
    Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Stephanie T P MezgerMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.
Alma M A MingelsCentral Diagnostic Laboratory, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht, The Netherlands.
Otto BekersCentral Diagnostic Laboratory, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ Maastricht, The Netherlands.
Ron M A HeerenMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.ORCID 0000-0002-6533-7179
Berta Cillero-PastorMaastricht MultiModal Molecular Imaging (M4I) Institute, Division of Imaging Mass Spectrometry, Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands.ORCID 0000-0002-7407-1165

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Mass spectrometry imaging (MSI) can analyze the spatial distribution of hundreds of different molecules directly from tissue sections usually placed on conductive glass slides to provide conductivity on the sample surface. Additional experiments are often required for molecular identification using consecutive sections on membrane slides compatible with laser capture microdissection (LMD). In this work, we demonstrate for the first time the use of a single conductive slide for both matrix-assisted laser desorption ionization (MALDI)-MSI and direct proteomics. In this workflow, regions of interest can be directly ablated with LMD while preserving protein integrity. These results offer an alternative for MSI-based multimodal spatial-omics.

Indexed as

Chromatography, LiquidLaser Capture MicrodissectionProteomicsSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationTandem Mass Spectrometry

Identifiers

PMID33412004
PMCPMC7859928

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.