ArticleEJNMMI radiopharmacy and chemistry2021
Implementation and validation of an in-house combined fluorescein/media-fill test to qualify radiopharmacy operators.
Article in EJNMMI radiopharmacy and chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Process-Related Incidents in Nuclear Medicine: A Four-Year Single-Center Retrospective Analysis to Support the Implementation of a Scenario-Based Radiopharmacy Training.Pharmacy (Basel, Switzerland) · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe purpose of this work was to design, validate and implement a media-fill test combined with fluorescein (MFT-F) for the specific qualification and training of radiopharmacy operators, in accordance with United States Pharmacopeia General Chapter 797 and European Good Manufacturing Practices. MFT-F was embedded in the quality management system of our radiopharmacy unit. Its validation involved fluorescein concentration choice, media growth promotion test and evaluation protocol controls (with or without intentional aseptic mistakes). Each operator was evaluated following a three-part evaluation form. Evaluation criteria related to garbing and hygiene, fluorescent contamination and bacteriological contamination (pre- and post-evaluation environment controls and MFT-F samples). Combined MFT-F allowed the assessment of aseptic compounding skills and non-contamination of the working area through a single evaluation. It was also designed to fit the constraints of radiopharmacy common practice related to radiation protection equipment and to the small volumes handled.
resultsA 0.01% fluorescein concentration was chosen to prepare MFT-F. Addition of fluorescein in the culture medium did not jeopardize its growth properties according to growth promotion test. Eleven operators were evaluated and carried out 3 MFT-F over 3 successive days. Pre- and post-evaluation bacteriological controls of every session showed no CFU of microbiological contaminant above 5. All operators validated the garbing and hygiene evaluation, with an average score of 92.7%. All operators validated the fluorescent contamination evaluation, with an average score of 29.4 out of 30. None of the MFT-F samples showed any visible bacterial growth after incubation.
conclusionsCombined MFT-F, as a part of a comprehensive sterile compounding training program, appeared as a convenient and promising tool to increase both the sterile compounding safety and awareness of radioactive contamination in radiopharmacy.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.