ArticleNeuroradiology2021
Two-center experience with Neuroform Atlas stent-assisted coil occlusion of broad-based intracranial aneurysms.
Article in Neuroradiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- Safety and Efficacy of the Neuroform Atlas Stent for Treatment of Intracranial Aneurysms: A Systematic Review, Meta-Analysis, and Meta-Regression.AJNR. American journal of neuroradiology · 2025Pooled it
- Mechanical behavior of functionally zoned hybrid intracranial stent integrating laser-cut and braided architectures.Frontiers in bioengineering and biotechnology · 2026Article
- Preliminary outcomes of Neuroform Atlas stent-assisted coiling for intracranial aneurysms with small parent vessels.Chinese neurosurgical journal · 2025Article
- Treatment of saccular wide-neck intracranial aneurysm using Leo baby stent: a single-center experience based on 156 cases.Neurosurgical review · 2024Article
- Safety and efficacy of the novel Alpha stent for the treatment of intracranial wide-necked aneurysm.Scientific reports · 2024Article
- Treatment of broad-based intracranial aneurysms with the LVIS EVO stent: a retrospective observational study at two centers with short- and medium-term follow-up.Scientific reports · 2023Observational
- Stretched and fractured Neuroform AtlasExperimental and therapeutic medicine · 2023Article
- Procedural Outcome Following Stent-Assisted Coiling for Wide-Necked Aneurysms Using Three Different Stent Models: A Single-Center Experience.Journal of clinical medicine · 2022Article
- Platelet function testing using the Multiplate analyzer after administration of aspirin in Aachen minipigs.PloS one · 2022Article
- Stent-assisted coiling using the Neuroform Atlas stent for treatment of aneurysms that recur after coil embolization.Frontiers in neurology · 2022Article
- Application of the Neuroform Atlas Stent in Intracranial Aneurysms: Current Status.Frontiers in neurology · 2022Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeStent-assisted coiling (SAC) represents an established treatment option for broad-based intracranial aneurysms. Here we report our initial and follow-up experience with the Neuroform Atlas Stent, a hybrid open- and closed-cell low-profile stent in the treatment of broad-based aneurysms.
methodsAll intracranial aneurysms treated by SAC with the intention to apply the Neuroform Atlas Stent between July 2015 and December 2019 were included. Angiographic and clinical results were analyzed including all follow-up examinations.
resultsA total of 119 aneurysms (8 acutely ruptured) in 112 patients were included. In 19 cases (16.0%) re-catheterization of the aneurysm was performed in a second procedure after failure to re-cross the stent initially. Of all aneurysms, 83.2% (99/119) were completely occluded following the procedure. In 75.6% of all cases (90/119), a single microcatheter was used for both, implantation of the stent and coil occlusion of the aneurysm. At 3-6 and 12 months follow-up, the complete occlusion rates were 75.2 (79/105) and 81.3% (74/91). The thromboembolic (stent thrombosis) and hemorrhagic complication rate was 1.7 (2/119) and 0.8% (1/119), respectively, resulting in a procedure-related morbidity and mortality rate of 0.9 and 0.9% (1/112 patients).
conclusionSAC using the Neuroform Atlas Stent offers a safe and effective option to treat broad-based intracranial aneurysms with a high angiographic and clinical success rate. In the majority of procedures, the application of two mircocatheters is not required. Prospective comparative studies might help to identify the value of SAC using the Neuroform Atlas Stent among the growing treatment options for broad-based aneurysms.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.