Evidence map›Paper›PMID 33410757›Full record

ArticleJMIR mHealth and uHealth2021

Validity of Wrist-Wearable Activity Devices for Estimating Physical Activity in Adolescents: Comparative Study.

Yingying Hao, Xiao-Kai Ma, Zheng Zhu, Zhen-Bo Cao

Abstract readComparative Study
In one paragraph

Article in JMIR mHealth and uHealth, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Agreement between Fitbit and ActiGraph Estimates of Physical Activity in Young Children.Measurement in physical education and exercise science · 2023
    Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Yingying HaoSchool of Kinesiology, Shanghai University of Sport, Shanghai, China.ORCID 0000-0001-7682-4063
Xiao-Kai MaSchool of Kinesiology, Shanghai University of Sport, Shanghai, China.ORCID 0000-0002-7618-397X
Zheng ZhuSchool of Kinesiology, Shanghai University of Sport, Shanghai, China.ORCID 0000-0002-5846-2510
Zhen-Bo CaoSchool of Kinesiology, Shanghai University of Sport, Shanghai, China.ORCID 0000-0002-2652-7279

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe rapid advancements in science and technology of wrist-wearable activity devices offer considerable potential for clinical applications. Self-monitoring of physical activity (PA) with activity devices is helpful to improve the PA levels of adolescents. However, knowing the accuracy of activity devices in adolescents is necessary to identify current levels of PA and assess the effectiveness of intervention programs designed to increase PA.

objectiveThe study aimed to determine the validity of the 11 commercially available wrist-wearable activity devices for monitoring total steps and total 24-hour total energy expenditure (TEE) in healthy adolescents under simulated free-living conditions.

methodsNineteen (10 male and 9 female) participants aged 14 to 18 years performed a 24-hour activity cycle in a metabolic chamber. Each participant simultaneously wore 11 commercial wrist-wearable activity devices (Mi Band 2 [XiaoMi], B2 [Huawei], Bong 2s [Meizu], Amazfit [Huamei], Flex [Fitbit], UP3 [Jawbone], Shine 2 [Misfit], GOLiFE Care-X [GoYourLife], Pulse O2 [Withings], Vivofit [Garmin], and Loop [Polar Electro]) and one research-based triaxial accelerometer (GT3X+ [ActiGraph]). Criterion measures were total EE from the metabolic chamber (mcTEE) and total steps from the GT3X+ (AGsteps).

resultsPearson correlation coefficients r for 24-hour TEE ranged from .78 (Shine 2, Amazfit) to .96 (Loop) and for steps ranged from 0.20 (GOLiFE) to 0.57 (Vivofit). Mean absolute percent error (MAPE) for TEE ranged from 5.7% (Mi Band 2) to 26.4% (Amazfit) and for steps ranged from 14.2% (Bong 2s) to 27.6% (Loop). TEE estimates from the Mi Band 2, UP3, Vivofit, and Bong 2s were equivalent to mcTEE. Total steps from the Bong 2s were equivalent to AGsteps.

conclusionsOverall, the Bong 2s had the best accuracy for estimating TEE and total steps under simulated free-living conditions. Further research is needed to examine the validity of these devices in different types of physical activities under real-world conditions.

Indexed as

Wearable Electronic DevicesWristAccelerometryAdolescentExerciseFemaleFitness TrackersHumansMaleReproducibility of Resultsaccelerometerenergy expenditurefree-livingstep countswrist-wearable activity devices

Identifiers

PMID33410757
PMCPMC7819784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked