Evidence map›Paper›PMID 33410089›Full record

ArticleJournal of fluorescence2021

Selective and Sensitive ZnO Quantum Dots Based Fluorescent Biosensor for Detection of Cysteine.

Umran Duru Kamaci, Musa Kamaci

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of fluorescence, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Progress in ZnO Nanosensors.Sensors (Basel, Switzerland) · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Umran Duru KamaciFaculty of Arts and Sciences, Department of Chemistry, Yildiz Technical University, 34220, Istanbul, Esenler, Turkey.ORCID https://orcid.org/0000-0003-2650-9107
Musa KamaciPiri Reis University, 34940, Istanbul, Tuzla, Turkey. mkamaci@pirireis.edu.tr.ORCID http://orcid.org/0000-0001-5865-7687

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In the present article, a novel and effective ZnO quantum dots-based fluorescent probe has been developed for the detection of cysteine in different solutions. Firstly, melamine-based fluorescent pre-probe was successfully synthesized via condensation reaction and, then ZnO quantum dots (QDs) were homogenously dispersed into this solution. This fluorescent probe was used for the detection of cysteine in different solutions such as bovine serum albumin and tap water. ZnO QDs were characterized using XRD, nano-particle size analyzer, and FE-SEM techniques. The size of the ZnO QDs was calculated as 28.03±9.86 nm, and 31.95±10.02 nm from Scherrer's equation and nano-particle size analyzer, respectively. The developed fluorescent probe was exhibited a highly selective and sensitive response to the detection of cysteine. Also, the proposed fluorescent probe has a larger Stokes shift value (236 nm). The limit of detection and linear range of ZnO QDs-based fluorescent biosensor were found as 0.642 μM and 0.1-600 μM, respectively. ZnO quantum dot-based fluorescent sensor for L-cysteine.

Indexed as

Biosensing TechniquesCysteineFluorescent DyesHydrogen-Ion ConcentrationMolecular StructureParticle SizeQuantum DotsSpectrometry, FluorescenceZinc OxideCysteineFluorescent DyesZinc OxideBiosensorBSACysteineMelamineZnO quantum dots

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.