Dual modal fluorescent colposcope combined with near-infrared fluorescent dye TMTP1-PEG4-ICG to detect cervical lesions.

Chen Wang, Ying Zhou, Wei Li, Xiaohu Liu, Ling Xi, Pengcheng Li, Juncheng Wei, Jinling Lu

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.2field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Chen WangBritton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Ying ZhouDepartment of Obstetrics and Gynecology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China.
Wei LiDepartment of Obstetrics and Gynecology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China.
Xiaohu LiuBritton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Ling XiDepartment of Obstetrics and Gynecology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China.
Pengcheng LiBritton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Juncheng WeiDepartment of Obstetrics and Gynecology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei 430030, China.
Jinling LuBritton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics-Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
Huazhong University of Science and Technology · CNWuhan National Laboratory for Optoelectronics · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To examine the cervical lesions by using the tumor-targeted near-infrared (NIR) fluorescent dyes TMTP1-PEG4-ICG, a dual modal colposcope with visible reflectance imaging and fluorescence imaging was developed. NIR fluorescence imaging and visible light reflectance imaging were integrated together on a colposcope by designing the specific optics and adopting a dual sensor charge coupled device (CCD) camera. Patients with squamous cell carcinoma, adenocarcinoma, cervical intraepithelial neoplasia (CIN) and cervicitis were examined using this dual modal colposcope to validate its potential of cervical cancer detection. Fluorescent dye TMTP1-PEG4-ICG was applied to the cervix 30 minutes before inspection. The fluorescence images were collected after wiping the unbound fluorescent dye using normal saline. Signal to back ratios (SBR) of the fluorescence images were analyzed and compared with the histological analysis. The results suggest that the fluorescent colposcope combined with tumor-specific near-infrared fluorescent dyes TMTP1-PEG4-ICG could help to evaluate cervical lesions in real time.

Identifiers

PMID33408984
PMCPMC7747887
OpenAlexW3095833310

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.