Evidence map›Paper›PMID 33406751›Full record

ArticleSensors (Basel, Switzerland)2021

Assessing the Potential of LPWAN Communication Technologies for Near Real-Time Leak Detection in Water Distribution Systems.

Michael Pointl, Daniela Fuchs-Hanusch

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 27 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Michael PointlInstitute of Urban Water Management and Landscape Water Engineering, Graz University of Technology, Stremayrgasse 10/I, 8010 Graz, Austria.ORCID 0000-0001-8623-8981
Daniela Fuchs-HanuschInstitute of Urban Water Management and Landscape Water Engineering, Graz University of Technology, Stremayrgasse 10/I, 8010 Graz, Austria.ORCID 0000-0002-9766-6962
Graz University of Technology · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

While low-power wide-area network (LPWAN) technologies have been studied extensively for a broad spectrum of smart city applications, their potential for water distribution system monitoring in high temporal resolution has not been studied in detail. However, due to their low power demand, these technologies offer new possibilities for operating pressure-monitoring devices for near real-time leak detection in water distribution systems (WDS). By combining long-distance wireless communication with low power consumption, LPWAN technologies promise long periods of maintenance-free device operation without having to rely on an external power source. This is of particular importance for pressure-based leak detection where optimal sensor positions are often located in the periphery of WDS without a suitable power source. To assess the potential of these technologies for replacing widely-used wireless communication technologies for leak detection, GPRS is compared with the LPWAN standards Narrowband IoT, long-range wide area network (LoRaWAN) and Sigfox. Based on sampling and transmission rates commonly applied in leak detection, the ability of these three technologies to replace GPRS is analyzed based on a self-developed low-power pressure-monitoring device and a simplified, linear energy-consumption model. The results indicate that even though some of the analyzed LPWAN technologies may suffer from contractual and technical limitations, all of them offer viable alternatives, meeting the requirements of leak detection in WDS. In accordance with existing research on data transmission with these technologies, the findings of this work show that even while retaining a compact design, which entails a limited battery capacity, pressure-monitoring devices can exceed runtimes of 5 years, as required for installation at water meters in Austria. Thus, LPWAN technologies have the potential to advance the wide application of near real-time, pressure-based leak detection in WDS, while simultaneously reducing the cost of device operation significantly.

Indexed as

leak detectionlow-power wide-area networkswater distribution system analysis

Identifiers

PMID33406751
PMCPMC7795417
OpenAlexW3119876969

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked