CT imaging of gold nanoparticles in a human-sized phantom.

Michael Oumano, Liz Russell, Morteza Salehjahromi, Lou Shanshan, Neeharika Sinha, Wilfred Ngwa, Hengyong Yu

Open access · goldAbstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.3field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 2 countries.

Michael OumanoMedical Physics Program, Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, USA.ORCID https://orcid.org/0000-0002-4404-2136
Liz RussellNeusoft Medical Systems USA, Houston, TX, USA.
Morteza SalehjahromiDepartment of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA.
Lou ShanshanNeusoft Medical Systems, Hunnan District, Shenyang, China.
Neeharika SinhaDepartment of Physics, Wentworth Institute of Technology, Boston, MA, USA.
Wilfred NgwaMedical Physics Program, Department of Physics and Applied Physics, University of Massachusetts Lowell, Lowell, MA, USA.
Hengyong YuDepartment of Electrical and Computer Engineering, University of Massachusetts Lowell, Lowell, MA, USA.
University of Massachusetts Lowell · USBrigham and Women's Hospital · USNeusoft (China) · CNWentworth Institute of Technology · US

Funding

Biomaterial Drones for Image-Guided Drug Delivery during radiotherapyR01CA239042 · NCI · JOHNS HOPKINS UNIVERSITY · PI NGWA, WILFRED · 2019 to 2023
$3.2M
NCI NIH HHS R01 CA239042
6 · The paper itself

Abstract

introductionGold nanoparticles (AuNPs) are visualized and quantified in a human-sized phantom with a clinical MDCT scanner.

methodsExperiments were conducted with AuNPs between 0.00171 and 200 mgAu/mL. CT images were acquired at 80, 100, 120, and 140 kVp in a 33-cm phantom. Image contrast due to AuNPs was experimentally determined from regions of interest (ROIs) and effective linear attenuation coefficients were calculated from CT x-ray spectra with consideration of tissue attenuation.

resultsThe typical 12-bit dynamic range of CT images was exceeded for AuNPs at 150 mgAu/mL. A threshold concentration of 0.3-1.4 mgAu/mL was determined for human visualization in 1-mm images at a typical diagnostic CTDI

conclusionsWe have shown that scanners capable of reconstructing images with extended Hounsfield scales are required for distinguishing any contrast differences above 150 mgAu/mL. We have also shown that AuNPs result in optimal image contrast at 120 kVp in a human-sized phantom due to gold's 80.7 keV k-edge and the attenuation of x-rays by tissue. Typical CT contrast agents, like iodine, require the use of lower kVps for optimal visualization, but lower kVps are more difficult to implement in the clinic because of elevated noise levels, elongated scan times, and/or beam-hardening artifacts. This indicates another significant advantage of AuNPs over iodine not yet discussed in the literature.

Indexed as

IodineMetal NanoparticlesGoldHumansPhantoms, ImagingTomography, X-Ray ComputedGoldIodineAuNPscontrast agentsgoldnanoparticlesx-rays