Observational studyTherapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy2021
Assessment of the accuracy of an intermittent-scanning continuous glucose monitoring device in patients with type 2 diabetes mellitus undergoing hemodialysis (AIDT2H) study.
Observational study in Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 23 citations in OpenAlex.
- Continuous glucose monitoring reveals distinct clinical implications of glucose levels at the start and end of hemodialysis in people with type 2 diabetes.BMC endocrine disorders · 2026Article
- Glycemic assessment when hemoglobin A1c is unreliable: a clinical-laboratory framework for kidney disease, anemia, and hemoglobinopathies.Frontiers in endocrinology · 2026Review
- Scoping Review-Diabetes Technology for Individuals on Kidney Replacement Therapy (Dialysis): Current Trends and Future Directions.Journal of diabetes science and technology · 2025Review
- Performance of an interstitial glucose monitoring device in patients with type 1 diabetes during haemodialysis.Clinical kidney journal · 2024Article
- Application and management of continuous glucose monitoring in diabetic kidney disease.World journal of diabetes · 2024Article
- Continuous glucose monitoring in people with diabetes and end-stage kidney disease-review of association studies and Evidence-Based discussion.Journal of nephrology · 2024Review
- Evaluation of a Fourth-Generation Subcutaneous Real-Time Continuous Glucose Monitor (CGM) in Individuals With Diabetes on Peritoneal Dialysis.Diabetes care · 2023Article
- Safety and Accuracy of Professional Continuous Glucose Monitoring in Patients Undergoing Allogeneic Hematopoietic Stem Cell Transplantation.Blood cell therapy · 2023Article
- CORRIGENDUM.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2022Article
- Diabetes Complications and Related Comorbidities Impair the Accuracy of FreeStyle Libre, a Flash Continuous Glucose Monitoring System, in Patients with Type 2 Diabetes.Diabetes, metabolic syndrome and obesity : targets and therapy · 2022Article
- Use of continuous glucose monitoring system in patients with type 2 mellitus diabetic during hemodialysis treatment.Diabetology & metabolic syndrome · 2021Article
- Assessment of the accuracy of an intermittent-scanning continuous glucose monitoring device in patients with type 2 diabetes mellitus undergoing hemodialysis (AIDT2H) study.Therapeutic apheresis and dialysis : official peer-reviewed journal of the International Society for Apheresis, the Japanese Society for Apheresis, the Japanese Society for Dialysis Therapy · 2021Observational
Corrections and comments
- Erratum issuedCORRIGENDUM.2022
Authors and funding
27 authors at 17 institutions in 2 countries.
Funding
Abstract
FreeStyle Libre has been approved for use in patients undergoing hemodialysis (HD) in Japan, unlike Europe and the United States; however, evidence regarding its accuracy in such patients is sparse. Forty-one participants with type 2 diabetes undergoing HD were recruited. The overall mean absolute relative difference and mean absolute difference were 23.4% and 33.9 mg/dL, respectively. Sensor glucose levels and capillary glucose levels were significantly correlated (r = 0.858, P < .01), although the sensor glucose levels were significantly lower than the capillary glucose levels. The accuracy of FreeStyle Libre in patients undergoing HD became deteriorated with the days of usage. The percentage of sensor results in Zones A and B in the consensus error grid analysis and in the Clarke error grid analysis were 99.7% and 99.0%, respectively. Its insufficient accuracy necessitates adjunct usage of FreeStyle Libre with self-monitoring of blood glucose in patients undergoing HD.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials