Evidence map›Paper›PMID 33402144›Full record

ArticleMalaria journal2021

A timed tally counter for microscopic examination of thick blood smears in malaria studies.

Grégory Nuel, André Garcia

Abstract read
In one paragraph

Article in Malaria journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Precision Medicine in Control of Visceral Leishmaniasis Caused byFrontiers in cellular and infection microbiology · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Grégory NuelStochastics and Biology Group, Probability and Statistics (LPSM, CNRS 8001), Sorbonne University, Campus Pierre et Marie Curie, 4 Place Jussieu, 75005, Paris, France. nuel@math.cnrs.fr.
André GarciaMERIT (IRD 261), University of Paris, Faculté de Pharmacie, 4 Avenue de l'Observatoire, 75006, Paris, France.

Funding

ANR ANR- 2010-PRSP-012 001 TOLIMMUNPALCNRS AMIES Timed Tally Counter
6 · The paper itself

Abstract

backgroundDespite many technological advances for malaria parasite detection (e.g. high resolution image acquisition), microscopic reading of thick blood smear (TBS) remains the gold standard. Even though available in low technology environment, the microscopy of TBS is slow and time consuming. Moreover microscopy may induce errors at many levels and has no quality control.

methodsA electronic extension of the mechanical tally counter is proposed. In addition to the counting process it includes the process of counting itself that relies on the time elapsed between two successive pressures of the counting button leading to a timed tally counter (TTC). The microscopist performs the reading with the specific instruction starting by counting, in each high power fields, leucocytes first and then parasites. The time-stamp of all pressures of counting buttons are recorded along with the nature of the count. The data are recorded internally in CSV format and are exportable. The detection of HPFs locations and leukocyte/parasite counts per HPFs is performed through a hidden semi-Markov model (with outliers) allowing both to take into account the known distribution of leukocyte per HPFs (using a negative binomial distribution) and the pauses and hesitation of the microscopist during the reading. Parameters are estimated via the expectation-maximization algorithm. Hyper-parameters are calibrated using expert annotations. Forward/backward recursions are used to obtain the HPFs locations.

resultsThis approach provides richer data at no extra cost. It has been demonstrated that the method can derive parasites per HPF, leukocytes per HPF, and parasite/leukocyte ratio with robust non-parametric confidence intervals. Moreover a direct digital data entry leads to a less expensive process and decreased time-consuming and error-prone manual data entry. Lastly the TTC allows detecting possible protocol break during reading and prevents the risk of fraud. DISCUSSION AND

conclusionIntroducing a programmed digital device in the data acquisition of TBS reading gives the opportunity to develop easily new (possible adaptive) reading protocols that will be easily followed by the reader since they will be embedded directly in the device. With the TTC the reader only has to read HPFs, counting leukocytes first and parasites second, and the counter will beep when the protocol is completed.

Indexed as

AlgorithmsHumansImage Processing, Computer-AssistedMalariaMicroscopyParasitemiaMalariaMicroscopeParasite densityQuality controlTimed tally counter

Identifiers

PMID33402144
PMCPMC7786463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.