ArticleJournal of synchrotron radiation2021
ROBL-II at ESRF: a synchrotron toolbox for actinide research.
Article in Journal of synchrotron radiation, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
44 citing papers in PubMed.
- Seeing redox at the microscale: 2D HERFD-XRF imaging of uranium oxidation states on thin sections of bacterial cells.RSC advances · 2026Article
- XAFS and DFT Insights into the Kinetics and Mechanisms of Technetium Reduction by Nanoparticulate Magnetite.Environmental science & technology · 2026Article
- Pressure-Induced Stabilization of Terbium(IV) in CsTb(CrOJournal of the American Chemical Society · 2026Article
- Stabilization of U(V) and U(VI) in Goethite Formed by Recrystallization of Fe-Oxyhydroxysulfates.Environmental science & technology · 2026Article
- Ruthenium Speciation during Acidification of Alkaline Solution.ACS omega · 2026Article
- Pentavalent and tetravalent uranium formation via glycerol-stimulated bacteria in mine water.Nature communications · 2026Article
- Unusual Magnetic Order in EuACS organic & inorganic Au · 2026Article
- Dispersion-compensated Rowland spectrometer: implications for uranium VB-RIXS.Journal of synchrotron radiation · 2026Article
- Single-Determinant Ground State in CeInorganic chemistry · 2025Article
- Bonding Trends in Pyridine-2-thiolato Complexes of Tetravalent Actinides.Inorganic chemistry · 2025Article
- Unveiling the Role of ZnClACS nano · 2025Article
- Crystal-field splitting strength of U-6d orbitals in NaUOJournal of synchrotron radiation · 2025Article
- SISYPHOS: An automatic procedure for the serial refinement of single-crystal diffraction data in Olex2.Structural dynamics (Melville, N.Y.) · 2025Article
- Relationship between Mineralogically Complex Iron (Oxyhydr)oxides and Plutonium Sorption and Reduction: A High-Energy Resolution X-ray Absorption Spectroscopy Perspective.Environmental science & technology · 2025Article
- Synthesis and quantum crystallographic evaluation of WYLID: YLID's red rival.Journal of applied crystallography · 2025Article
- Exploring Metastable Phases in Cerium-Doped Zirconia: Insights from X-ray Diffraction, Raman, X-ray Absorption, and Luminescence Spectroscopy.Inorganic chemistry · 2025Article
- Immobilization of Chromium by Iron Oxides in Nickel-Cobalt Laterite Mine Tailings.Environmental science & technology · 2025Article
- Advanced 2D XRF imaging of uranium oxidation states using HERFD at the U MChemical communications (Cambridge, England) · 2025Article
- Elucidation of the Off-Center Displaced Mo in Octahedral Coordination in BaInorganic chemistry · 2025Article
- Exploring cluster formation in uranium oxidation using high resolution X-ray spectroscopy at elevated temperatures.Communications materials · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
17 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
ROBL-II provides four different experimental stations to investigate actinide and other alpha- and beta-emitting radionuclides at the new EBS storage ring of ESRF within an energy range of 3 to 35 keV. The XAFS station consists of a highly automatized, high sample throughput installation in a glovebox, to measure EXAFS and conventional XANES of samples routinely at temperatures down to 10 K, and with a detection limit in the sub-p.p.m. range. The XES station with its five bent-crystal analyzer, Johann-type setup with Rowland circles of 1.0 and 0.5 m radii provides high-energy resolution fluorescence detection (HERFD) for XANES, XES, and RIXS measurements, covering both actinide L and M edges together with other elements accessible in the 3 to 20 keV energy range. The six-circle heavy duty goniometer of XRD-1 is equipped for both high-resolution powder diffraction as well as surface-sensitive CTR and RAXR techniques. Single crystal diffraction, powder diffraction with high temporal resolution, as well as X-ray tomography experiments can be performed at a Pilatus 2M detector stage (XRD-2). Elaborate radioprotection features enable a safe and easy exchange of samples between the four different stations to allow the combination of several methods for an unprecedented level of information on radioactive samples for both fundamental and applied actinide and environmental research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.