Evidence map›Paper›PMID 33396196›Full record

ArticleMolecules (Basel, Switzerland)2020

Exhaled Breath and Oxygenator Sweep Gas Propionaldehyde in Acute Respiratory Distress Syndrome.

Agnes S Meidert, Alexander Choukèr, Siegfried Praun, Gustav Schelling, Michael E Dolch

Open access · goldAbstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 11 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Agnes S MeidertDepartment of Anesthesiology, University Hospital of Munich-Campus Großhadern, Ludwig-Maximilians-University of Munich, 81366 Munich, Germany.
Alexander ChoukèrDepartment of Anesthesiology, University Hospital of Munich-Campus Großhadern, Ludwig-Maximilians-University of Munich, 81366 Munich, Germany.
Siegfried PraunV&F Analyse-und Messtechnik GmbH, Andreas Hofer Strasse 15, 6067 Absam, Austria.
Gustav SchellingDepartment of Anesthesiology, University Hospital of Munich-Campus Großhadern, Ludwig-Maximilians-University of Munich, 81366 Munich, Germany.ORCID 0000-0002-6538-0652
Michael E DolchDepartment of Anesthesiology, University Hospital of Munich-Campus Großhadern, Ludwig-Maximilians-University of Munich, 81366 Munich, Germany.
Ludwig-Maximilians-Universität München · DE

Funding

European Space Agency ELIPS 3 programmeFederal Ministry of Economics and Technology 50WB0719, 50WB0919
6 · The paper itself

Abstract

backgroundOxidative stress-induced lipid peroxidation (LPO) due to neutrophil-derived reactive oxygen species plays a key role in the early stage of the acute respiratory distress syndrome (ARDS). Monitoring of oxidative stress in this patient population is of great interest, and, ideally, this can be done noninvasively. Recently, propionaldehyde, a volatile chemical compound (VOC) released during LPO, was identified in the breath of lung transplant recipients as a marker of oxidative stress. The aim of the present study was to identify if markers of oxidative stress appear in the oxygenator outflow gas of patients with severe ARDS treated with veno-venous extracorporeal membrane oxygenation (ECMO).

methodsThe present study included patients with severe ARDS treated with veno-venous ECMO. Concentrations of acetone, isoprene, and propionaldehyde were measured in inspiratory air, exhaled breath, and oxygenator inflow and outflow gas at corresponding time points. Ion-molecule reaction mass spectrometry was used to measure VOCs in a sequential order within the first 24 h and on day three after ECMO initiation.

resultsNine patients (5 female, 4 male; age = 42.1 ± 12.2 year) with ARDS and already established ECMO therapy (pre-ECMO PaO

conclusionsAcetone, isoprene, and propionaldehyde appear in breath and oxygenator outflow gas in comparable amounts. This allows for the measurement of these VOCs in a critically ill patient population via the ECMO oxygenator outflow gas without the need of ventilator circuit manipulation.

Indexed as

AdolescentAdultAldehydesBreath TestsExtracorporeal Membrane OxygenationFemaleHumansMaleMiddle AgedOxygenatorsPilot ProjectsRespiration, ArtificialRespiratory Distress SyndromeAldehydespropionaldehydeacute respiratory distress syndromebreath gas analysisextracorporeal membrane oxygenationoxidative stresspropionaldehyde

Identifiers

PMID33396196
PMCPMC7796205
OpenAlexW3113469378

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.