Efficacy of a Novel Intraoperative Engineered Sharps Injury Prevention Device: Pilot Usability and Efficacy Trial.
Article in JMIR perioperative medicine, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 2 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe American College of Surgeons reports 88,320 intraoperative needlestick injuries (NSIs) per year, resulting in US $376 to US $2456 in costs per NSI. Engineered sharps injury prevention (ESIP) devices protect against NSIs. To our knowledge, no study has been published to date to demonstrate clinical effectiveness of an intraoperative ESIP device. Operative Armour is a wearable arm cuff that can be donned during surgical closure to allow surgeons to keep a suture pack and sharps protection container on their forearm.
objectiveWe characterize Operative Armour's ESIP device effectiveness in a tertiary hospital, hypothesizing that this device will decrease NSI risk by decreasing behaviors associated with NSIs: needle passing and handling.
methodsA prospective case-control study was conducted with institutional review board quality improvement designation in which authors observed skin closures of plastic surgery procedures. To ensure accuracy, one surgeon was observed at a time. Control surgeries were purely observational; intervention cases involved surgeon use of the device during skin closure. Outcomes of interest included needle passing, needle handling, lost needles, and loaded waiting needles.
resultsSurgeons were observed in 50 control and 50 intervention cases. Operative Armour eliminated needle passing during skin closure. One NSI occurred in one control case; no NSIs were observed in intervention cases (P=.36). The mean number of loaded and unprotected waiting needles was also significantly decreased in the intervention group from 2.3 to 0.2 (P<.001). Furthermore, a multivariable linear regression established that Operative Armour significantly decreased the number of needle adjustments by hand per stitch observed (F
conclusionsOperative Armour effectively functions as an ESIP device by decreasing intraoperative needle passing and handling. Although sample size prohibits demonstrating a decrease in NSIs during observed cases, by decreasing behaviors that drive NSI risk, we anticipate an associated decrease in NSIs with use of the device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.