Evidence map›Paper›PMID 33392166›Full record

ArticleFrontiers in bioengineering and biotechnology2020

Verification of Finger Joint Stiffness Estimation Method With Soft Robotic Actuator.

Xiang Qian Shi, Ho Lam Heung, Zhi Qiang Tang, Kai Yu Tong, Zheng Li

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Xiang Qian ShiDepartment of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong.
Ho Lam HeungDepartment of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong.
Zhi Qiang TangDepartment of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong.
Kai Yu TongDepartment of Biomedical Engineering, The Chinese University of Hong Kong, Shatin, Hong Kong.
Zheng LiDepartment of Surgery, The Chinese University of Hong Kong, Shatin, Hong Kong.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Stroke has been the leading cause of disability due to the induced spasticity in the upper extremity. The constant flexion of spastic fingers following stroke has not been well described. Accurate measurements for joint stiffness help clinicians have a better access to the level of impairment after stroke. Previously, we conducted a method for quantifying the passive finger joint stiffness based on the pressure-angle relationship between the spastic fingers and the soft-elastic composite actuator (SECA). However, it lacks a ground-truth to demonstrate the compatibility between the SECA-facilitated stiffness estimation and standard joint stiffness quantification procedure. In this study, we compare the passive metacarpophalangeal (MCP) joint stiffness measured using the SECA with the results from our designed standalone mechatronics device, which measures the passive metacarpophalangeal joint torque and angle during passive finger rotation. Results obtained from the fitting model that concludes the stiffness characteristic are further compared with the results obtained from SECA-Finger model, as well as the clinical score of Modified Ashworth Scale (MAS) for grading spasticity. These findings suggest the possibility of passive MCP joint stiffness quantification using the soft robotic actuator during the performance of different tasks in hand rehabilitation.

Indexed as

metacarpophalangeal jointpassive joint stiffnessSECA-finger modelingsoft-elastic composite actuator (SECA)spasticitystroke

Identifiers

PMID33392166
PMCPMC7775510

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.