Evidence map›Paper›PMID 33392034›Full record

ArticleQuantitative imaging in medicine and surgery2021

Improved second harmonic generation and two-photon excitation fluorescence microscopy-based quantitative assessments of liver fibrosis through auto-correction and optimal sampling.

Chih-Yang Hsiao, Xiao Teng, Tung-Hung Su, Po-Huang Lee, Jia-Horng Kao, Kai-Wen Huang

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Chih-Yang HsiaoGraduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei.
Xiao TengHistoIndex Pte Ltd., Singapore.
Tung-Hung SuGraduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei.
Po-Huang LeeGraduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei.
Jia-Horng KaoGraduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei.
Kai-Wen HuangGraduate Institute of Clinical Medicine, National Taiwan University College of Medicine, Taipei.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSecond harmonic generation (SHG)/two-photon excited fluorescence (TPEF) microscopy is commonly used for the quantitative assessment of liver fibrosis; however, the accuracy is susceptible to sampling error and count error due to disturbances induced by some forms of collagen in liver specimens. In this study, we sought to improve the accuracy of quantitative assessments by removing the effects of this disturbing collagen and optimizing the sampling protocol.

methodsLarge liver resection samples from 111 patients with chronic hepatitis B were scanned using SHG/TPEF microscopy with multiple adjacent images. During the quantitative assessment, we then removed SHG signals associated with three types of extraneous physiological collagen: large patches of collagen near the boundary of the capsule, collagen around tubular structures, and collagen associated with distorted vessel walls. The optimal sampling protocol was identified by comparing scans from regions of interest of various sizes (3×3 tiles and 5×5 tiles) with full scans of the same tissue.

resultsThe proposed auto-correction algorithm detected 88 of 97 (90.7%) disturbing collagen on the images from the validation set. Removing these signals of disturbing collagen improved the correlation between Metavir stage and quantification of all 41 proposed collagen features. Through optimal sampling, five scans of 5×5 tiles or ten scans of 3×3 tiles were sufficient to minimize the mean error rate to around 2% of collagen percentage quantification and to achieve similar correlations around 0.27 with Metavir stage as using full tissue scans.

conclusionsOur results demonstrate that the quantitative assessments of liver fibrosis can be greatly enhanced in terms of accuracy and efficiency through optimal sampling and the automated removal of disturbing collagen signals. These types of image processing could be integrated in next-generation SHG/TPEF microscopic systems.

Indexed as

auto-correctionLiver fibrosisquantitative assessmentsampling error

Identifiers

PMID33392034
PMCPMC7719928

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.