Evidence map›Paper›PMID 33391907›Full record

ArticleCureus2020

Effect of Ureteral Stent Length and Position of Stent Coil in Bladder on Stent-Related Symptoms and Quality of Life of Patients.

Ketan Mehra, Ramanitharan Manikandan, Lalgudi N Dorairajan, Sreerag Sreenivasan Kodakkattil, Sidhartha Kalra

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Ketan MehraUrology and Renal Transplantation, Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry, IND.
Ramanitharan ManikandanUrology and Renal Transplantation, Jawaharlal Institute of Postgraduate Medical Education and Research, Pondicherry, IND.
Lalgudi N DorairajanUrology and Renal Transplantation, Jawaharlal Institute of Post Graduate Medical Education and Research, Pondicherry, IND.
Sreerag Sreenivasan KodakkattilUrology and Renal Transplantation, Jawaharlal Institute of Post Graduate Medical Education and Research, Pondicherry, IND.
Sidhartha KalraUrology and Renal Transplantation, Jawaharlal Institute of Post Graduate Medical Education and Research, Pondicherry, IND.
Jawaharlal Institute of Post Graduate Medical Education and Research · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionVarious standardized questionnaires can evaluate ureteral stent-related symptoms. The present study utilized a validated instrument, Ureteral Stent Symptoms Questionnaire (USSQ), to know the impact of the length of double J stent (DJS) in comparison to ureter length on patients and their quality of living. MATERIALS AND

methodThis study is a prospective clinical study conducted in the Department of Urology at a tertiary care center in South India. Patients who underwent DJS after endoscopic ureteral lithotripsy were included in the study. On a computerized tomography scan, the ureteral to stent length ratio (USR) was calculated. USSQ scores at the time of DJS removal and two weeks thereafter were recorded. The distal coil of the stent in the bladder was recorded as grade 1 - not crossing the midline and grade 2 - crossing the midline. Different symptom scores were compared between both grades of bladder coil and for USR of all the patients.

resultA total of 157 patients were included in the study. Over 46 (29.3%) patients had grade-1 and 111 (70.7%) had grade-2 bladder coil. Totally 93 (59.23%) patients reported pain, while 64 (40.77%) patients had no pain. Grade-2 coil patients had more pain than grade 1 (P=0.01). There was a weak inverse relationship between the USR and urinary symptom (P=0.004), pain symptom (P=0.04), and quality of work (P=0.005).

conclusionStent length or position of the intravesical stent coil does not appear to affect the quality of life except for the pain. Hence, choosing stent length according to ureteral length seems to have a minimal role in decreasing stent-related morbidity.

Indexed as

calculusstentureterureteral stent symptom

Identifiers

PMID33391907
PMCPMC7769726
OpenAlexW3108930837

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.