Evidence map›Paper›PMID 33390899›Full record

ArticleFrontiers in neuroscience2020

Recording of Electrically Evoked Neural Activity and Bladder Pressure Responses in Awake Rats Chronically Implanted With a Pelvic Nerve Array.

Sophie C Payne, Nicole M Wiedmann, Calvin D Eiber, Agnes W Wong, Philipp Senn, Peregrine B Osborne, Janet R Keast, James B Fallon

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.4field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Sophie C PayneBionics Institute, Fitzroy, VIC, Australia.
Nicole M WiedmannDepartment of Anatomy and Neuroscience, University of Melbourne, Melbourne, VIC, Australia.
Calvin D EiberDepartment of Anatomy and Neuroscience, University of Melbourne, Melbourne, VIC, Australia.
Agnes W WongDepartment of Anatomy and Neuroscience, University of Melbourne, Melbourne, VIC, Australia.
Philipp SennBionics Institute, Fitzroy, VIC, Australia.
Peregrine B OsborneDepartment of Anatomy and Neuroscience, University of Melbourne, Melbourne, VIC, Australia.
Janet R KeastDepartment of Anatomy and Neuroscience, University of Melbourne, Melbourne, VIC, Australia.
James B FallonBionics Institute, Fitzroy, VIC, Australia.
University of Melbourne · AUBionics Institute · AU

Funding

Understanding functional connectivity of sensory and motor pathways to specific regions of the lower urinary tract.OT2OD023872 · OD · UNIVERSITY OF MELBOURNE · PI KEAST, JANET R · 2016 to 2021
$5.3M
NIH HHS OT2 OD023872
6 · The paper itself

Abstract

Bioelectronic medical devices are well established and widely used in the treatment of urological dysfunction. Approved targets include the sacral S3 spinal root and posterior tibial nerve, but an alternate target is the group of pelvic splanchnic nerves, as these contain sacral visceral sensory and autonomic motor pathways that coordinate storage and voiding functions of the bladder. Here, we developed a device suitable for long-term use in an awake rat model to study electrical neuromodulation of the pelvic nerve (homolog of the human pelvic splanchnic nerves). In male Sprague-Dawley rats, custom planar four-electrode arrays were implanted over the distal end of the pelvic nerve, close to the major pelvic ganglion. Electrically evoked compound action potentials (ECAPs) were reliably detected under anesthesia and in chronically implanted, awake rats up to 8 weeks post-surgery. ECAP waveforms showed three peaks, with latencies that suggested electrical stimulation activated several subpopulations of myelinated A-fiber and unmyelinated C-fiber axons. Chronic implantation of the array did not impact on voiding evoked in awake rats by continuous cystometry, where void parameters were comparable to those published in naïve rats. Electrical stimulation with chronically implanted arrays also induced two classes of bladder pressure responses detected by continuous flow cystometry in awake rats: voiding contractions and non-voiding contractions. No evidence of tissue pathology produced by chronically implanted arrays was detected by immunohistochemical visualization of markers for neuronal injury or noxious spinal cord activation. These results demonstrate a rat pelvic nerve electrode array that can be used for preclinical development of closed loop neuromodulation devices targeting the pelvic nerve as a therapy for neuro-urological dysfunction.

Indexed as

continencemicturitionneuromodulationpelvic ganglionsplanchnic nerve

Identifiers

PMID33390899
PMCPMC7773906
OpenAlexW3111374202

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.