ArticleInternational journal of computer assisted radiology and surgery2021
A tactile sensor using the acoustic reflection principle for assessing the contact force component in laparoscopic tumor localization.
Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Tactile force sensor based on a modified acoustic reflection principle for intraoperative tumor localization in minimally invasive surgery.International journal of computer assisted radiology and surgery · 2026Article
- In Vivo Study on the Safe Use of a Novel Intraoperative Sensing Tool for Tissue Stiffness Assessment in Endoscopic Surgery.Biosensors · 2025Article
- Directional touch sensing for stiffness singularity search in an object using microfinger with tactile sensor.Scientific reports · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
purposeLocalization of an early stage gastric tumor is easily performed in conventional open surgery, whereas it is a difficult procedure in minimally invasive surgery (MIS). A tactile sensor could allow precise resection of the tumor in laparoscopic surgery. The safety of medical tools should be ensured in MIS. Moreover, boundary conditions such as a double-ended beam without a supporting rigid base during tissue palpation were hardly considered. Thus, we suppose that it is informative to assess the normal force and shear force for practical tumor detection considering the boundary condition.
methodsIn this study, a tactile sensor with normal and shear force measurement functions using the acoustic reflection principle was developed for gastric tumor detection in MIS. The developed tactile sensor was tested using an artificial phantom of the stomach without a supporting rigid base to evaluate the force response of the sensor in intraoperative tumor localization.
resultsThe developed sensor is safe for human tissue and can be sterilized. The experimental results show that the developed tactile sensor has the capability to measure normal and shear forces. In the gastric tumor detection test, the shear force of the sensor was more stable and highly responsive to the tumor position than the normal force, which is greatly affected by the bending of the tissue during the operation.
conclusionsA two-axis tactile sensor using the acoustic reflection principle was assembled for tissue palpation in MIS. The results showed that the developed sensor is suitable for tumor detection, indicating that the shear force information of the developed sensor is more useful in MIS for early stage gastric tumor localization.