Evidence map›Paper›PMID 33389604›Full record

ArticleInternational journal of computer assisted radiology and surgery2021

A tactile sensor using the acoustic reflection principle for assessing the contact force component in laparoscopic tumor localization.

Hiep Hoang Ly, Yoshihiro Tanaka, Michitaka Fujiwara

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Hiep Hoang LyDepartment of Electrical and Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Japan. h.ly.944@nitech.jp.ORCID http://orcid.org/0000-0002-7878-6053
Yoshihiro TanakaDepartment of Electrical and Mechanical Engineering, Graduate School of Engineering, Nagoya Institute of Technology, Nagoya, Japan.ORCID https://orcid.org/0000-0001-7917-1379
Michitaka FujiwaraDepartment of Gastroenterological Surgery, Graduate School of Medicine, Nagoya University, Nagoya, Japan.

Funding

Japan Society for the Promotion of Science JP17H01252Japan Society for the Promotion of Science JP19J23169
6 · The paper itself

Abstract

purposeLocalization of an early stage gastric tumor is easily performed in conventional open surgery, whereas it is a difficult procedure in minimally invasive surgery (MIS). A tactile sensor could allow precise resection of the tumor in laparoscopic surgery. The safety of medical tools should be ensured in MIS. Moreover, boundary conditions such as a double-ended beam without a supporting rigid base during tissue palpation were hardly considered. Thus, we suppose that it is informative to assess the normal force and shear force for practical tumor detection considering the boundary condition.

methodsIn this study, a tactile sensor with normal and shear force measurement functions using the acoustic reflection principle was developed for gastric tumor detection in MIS. The developed tactile sensor was tested using an artificial phantom of the stomach without a supporting rigid base to evaluate the force response of the sensor in intraoperative tumor localization.

resultsThe developed sensor is safe for human tissue and can be sterilized. The experimental results show that the developed tactile sensor has the capability to measure normal and shear forces. In the gastric tumor detection test, the shear force of the sensor was more stable and highly responsive to the tumor position than the normal force, which is greatly affected by the bending of the tissue during the operation.

conclusionsA two-axis tactile sensor using the acoustic reflection principle was assembled for tissue palpation in MIS. The results showed that the developed sensor is suitable for tumor detection, indicating that the shear force information of the developed sensor is more useful in MIS for early stage gastric tumor localization.

Indexed as

TouchAcousticsHumansLaparoscopyMechanical PhenomenaMinimally Invasive Surgical ProceduresNeoplasmsPalpationStomachStomach NeoplasmsAcoustic reflectionMinimally invasive surgeryShear forceTactile sensorTumor localization

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked