Evidence map›Paper›PMID 33389064›Full record

Observational studyHeart and vessels2021

Functional assessment of intermediate coronary artery stenosis with 4-Fr catheters.

Kazutaka Nogi, Tsunenari Soeda, Masahiko Hara, Hajime Iwama, Nozomi Toyokawa, Satoshi Sakai, Hiroki Yano, Atsushi Iwai, Yukihiro Hashimoto, Hajime Fujimoto and 4 more

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Heart and vessels, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 99% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors at 2 institutions in 1 country.

Kazutaka NogiDepartment of Cardiovascular Medicine, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan.
Tsunenari SoedaDepartment of Cardiovascular Medicine, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan. tsunenari0414@hotmail.com.ORCID http://orcid.org/0000-0001-5386-584X
Masahiko HaraCenter for Community-Based Healthcare Research and Education, Shimane University, Izumo, Japan.
Hajime IwamaDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Nozomi ToyokawaDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Satoshi SakaiDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Hiroki YanoDepartment of Cardiovascular Medicine, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan.
Atsushi IwaiDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Yukihiro HashimotoDepartment of Cardiovascular Medicine, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan.
Hajime FujimotoDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Megumi SuzukiDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Takehito NakaiDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Naofumi DoiDepartment of Cardiovascular Medicine, Nara Prefecture Seiwa Medical Center, Sango, Japan.
Yoshihiko SaitoDepartment of Cardiovascular Medicine, Nara Medical University, 840 Shijo-cho, Kashihara, 634-8522, Japan.
Nara Medical University · JPShimane University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The 4-Fr catheter system is not recommended for invasive functional assessment of coronary artery stenosis, because it tends to distort the aortic waveform. This study aimed to identify the incidence of aortic waveform distortion and a feasible method for correct diagnosis of coronary artery stenosis with a 4-Fr catheter. We retrospectively investigated 178 lesions with intermediate coronary artery stenosis. Non-hyperemic distal coronary artery pressure (Pd) and aortic pressure (Pa) were measured with a 4-Fr diagnostic or 6-Fr guiding catheter before and after saline flush. The mean Pd/mean Pa (Pd/Pa) and instantaneous wave-free ratio (iFR) were calculated before and after flushing. We compared the effect of flushing on the changes in Pd/Pa and iFR between the 4-Fr diagnostic and 6-Fr guiding catheters. Using the 4-Fr diagnostic catheter, there was a significant decrease in incidence of aortic waveform distortion from 42.0% (47 lesions) before flushing to 1.8% (2 lesions) after flushing (p < 0.001); the incidence was only 3.0% before saline flush and decreased to 0% after saline flush when using the 6-Fr guiding catheter. The presence of aortic waveform distortion influenced the iFR when the 4-Fr system was used. Functional measurements with the 4-Fr diagnostic catheter require adequate saline flush to remove the influence of aortic waveform distortion.

Indexed as

AgedCardiac CatheterizationCoronary AngiographyCoronary StenosisCoronary VesselsFemaleFollow-Up StudiesFractional Flow Reserve, MyocardialHumansMaleRetrospective StudiesROC CurveSeverity of Illness IndexCoronary artery diseaseFractional flow reserveFunctional coronary assessmentInstantaneous wave-free ratioPd/pa

Identifiers

PMID33389064
OpenAlexW3120492642

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.