ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2021
New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate.
Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures.Archives of orthopaedic and trauma surgery · 2026Article
- Evaluating three internal fixation techniques for Pauwels III femoral neck fractures via finite element analysis.Scientific reports · 2024Article
- Biomechanical changes in the proximal femur before and after removal of femoral neck system.Journal of orthopaedic surgery and research · 2024Article
- Design considerations for patient-specific bone fixation plates: a literature review.Medical & biological engineering & computing · 2023Review
- Evaluation of full thread screw and different fixation configurations in Pauwels type III femoral neck fracture.Heliyon · 2023Article
- Biomechanical study on parallel cannulated compression screw combined with medial buttress plate fixation and F-type cannulated compression screw fixation in Pauwels III femoral neck fracture:A finite element analysis.Zhong nan da xue xue bao. Yi xue ban = Journal of Central South University. Medical sciences · 2022Article
- In Silico Finite Element Modeling of Stress Distribution in Osteosynthesis after Pertrochanteric Fractures.Journal of clinical medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveIn this study, we aimed to evaluate the biomechanical behavior of three fixations for Pauwels type III fractures (sliding hip screw (SHS), L-shaped, and L-shaped with medial plate), by finite element analysis (FEM).
methodsThree internal fixators were developed to treat Pauwels type III fracture by finite elements: SHS; L-shaped; and L-shaped with medial plate. Under the same conditions, localized and total vertical fracture displacement, maximum and minimum principal and von Mises stresses were evaluated.
resultsThe localized and total vertical displacement evaluated for the SHS, L-shaped, and L-shaped with medial plate were 0.15 mm, 0.17 mm, and 0.07 mm (localized), and 4.52 mm, 6.97 mm, and 6.83 mm (total), respectively. The maximum values obtained in the upper region of the femoral neck for the internal fixations were 1.43 MPa, 1.29 MPa, and 1.24 MPa, and the minimum values obtained in the lower region of the femoral neck were - 0.73 MPa, - 1.09 MPa, and - 1.03 MPa, respectively. The maximum Von Mises peak stress values were 6.35 MPa, 10.7 MPa, and 16.2 MPa for the fixation models using the SHS, L-shaped, and L-shaped with medial plate, respectively.
conclusionThe present FEM analysis showed that SHS yields better results in terms of total vertical displacements, maximum distribution, and Von Mises peak stresses reduction. On the other hand, the L-shaped construction plus a medial plate decreases localized vertical displacements and maximum principal distribution when compared to the SHS and L-shaped constructions. These results demonstrate that both constructions, SHS and L-shaped plus a medial plate, are biomechanically efficient for the fixation of Pauwels type III femoral neck fractures.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.