Evidence map›Paper›PMID 33388874›Full record

ArticleCardiovascular and interventional radiology2021

Percutaneous Transpedicular Fixation by PEEK Polymer Implants Combined with Cementoplasty for Vertebral Compression Fractures: A Pilot Study.

F H Cornelis, M Barral, J C Le Huec, F Deschamps, T De Baere, L Tselikas

Abstract read
PubMed Publisher
In one paragraph

Article in Cardiovascular and interventional radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.3field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Polyetheretherketone Polymer Transpedicular Vertebral System to Treat Vertebral Compression Fracture: A Multicentre Pilot Study of Feasibility and Safety.Canadian Association of Radiologists journal = Journal l'Association canadienne des radiologistes · 2024
    Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

F H CornelisDepartment of Interventional Radiology, Tenon Hospital, APHP.Sorbonne Université, 4 rue de la Chine, 75020, Paris, France. francois.cornelis@aphp.fr.ORCID http://orcid.org/0000-0002-1058-0884
M BarralDepartment of Interventional Radiology, Tenon Hospital, APHP.Sorbonne Université, 4 rue de la Chine, 75020, Paris, France.
J C Le HuecPolyclinique Bordeaux Nord Aquitaine, Institut Européen du Dos - VERTEBRA, 15 Rue Claude Boucher, 33000, Bordeaux, France.
F DeschampsDepartment of Interventional Radiology, Gustave Roussy, 114 Rue Edouard Vaillant, 94800, Villejuif, France.
T De BaereDepartment of Interventional Radiology, Gustave Roussy, 114 Rue Edouard Vaillant, 94800, Villejuif, France.
L TselikasDepartment of Interventional Radiology, Gustave Roussy, 114 Rue Edouard Vaillant, 94800, Villejuif, France.
Institut Gustave Roussy · FRSorbonne Université · FRPolyclinique Bordeaux Nord Aquitaine · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the feasibility and safety of percutaneous transpedicular fixation by PEEK polymer implants and cementoplasty for vertebral compression fracture (VCF). MATERIALS AND

methodsFrom February 2019 to December 2019, 6 consecutive patients (3 men and 3 women; mean age 55 ± 8 years; range 40-64 years) who had percutaneous transpedicular fixation with cementoplasty for the treatment of VCF (5 tumor lesions, 1 traumatic) were included. The procedure duration, length of hospital stay, and complications were reported. Visual analog scale (VAS) and the Oswestry disability index (ODI) for pain and disability were assessed before and 2 months after the procedure.

resultsThe mean procedure duration was 74 ± 47 min (range 20-140 min). The median length of hospital stay was 3 days (range 2-63) after the procedure. Only minor adverse events were reported (4 asymptomatic cement leakages) but no severe complications. No cases of procedural site fracture during follow-up were noted (median 198 days; range 78-238 days). The mean VAS score decreased from 6.2 ± 1.8 mm (median 6 mm; range 4-9 mm) before the procedure to 1.7 ± 2.1 mm (median 1; range 0-5 mm) after the procedure. The ODI decreased from 36 ± 14% (range 18-54%) before the procedure to 23 ± 10% (range 11-30%) at 2-months follow-up.

conclusionsPercutaneous transpedicular fixation of VCF by PEEK implants with cementoplasty appears feasible and safe.

Indexed as

Bone CementsKetonesPolyethylene GlycolsAdultBenzophenonesCementoplastyCone-Beam Computed TomographyFemaleFracture Fixation, InternalFractures, CompressionHumansLumbar VertebraeMaleMiddle AgedPilot ProjectsPolymersBenzophenonesBone CementsKetonespolyetheretherketonePolyethylene GlycolsPolymersCancerOsteoporosisSpineTranspedicular fixationVertebroplasty

Identifiers

PMID33388874
OpenAlexW3119769596

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked