ArticleRadiological physics and technology2021
Evaluation of the homogeneity of native T1 myocardial mapping using the polarity corrected inversion time preparation method in a myocardial phantom and healthy volunteers.
Article in Radiological physics and technology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 5 citations in OpenAlex.
- Novel T1 Analysis Method to Address Reduced Measurement Accuracy Due to Irregular Heart Rate Variability in Myocardial T1 Mapping Using Polarity-corrected Inversion Time Preparation.Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine · 2025Article
- Native myocardial TRadiological physics and technology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Myocardial T1 mapping is a useful technique for the diagnosis of diffuse fibrosis. Although modified look-locker inversion recovery is a widely used T1 mapping method, variation in T1 values has been reported. Non-uniform T1 maps may hinder differentiation between healthy and diseased myocardial tissue. The purpose of this study was to investigate the uniformity of T1 mapping using polarity corrected inversion time preparation (PC TI prep) in a myocardial phantom and healthy volunteers. The myocardial phantom was scanned between polyvinyl alcohol (PVA) and air. T1 values were measured using inversion recovery fast spin-echo (IR-FSE) and PC TI prep in areas adjacent to PVA and air. For the volunteer study, the short-axis plane was imaged using the PC TI prep to compare T1 values in the myocardium of the septal and lateral walls. The T1 value of the phantom using the IR-FSE was not significantly different in the area between PVA and air, whereas the T1 value using the PC TI prep in the air area was significantly lower than that in the PVA area. T1 mapping of the healthy myocardium exhibited no significant difference between the septal and lateral walls. The T1 value using the PC TI prep in the air area was 6.3% lower than that using IR-FSE. In this study, T1 mapping using the PC TI prep exhibited high uniformity of T1 values.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.