Evidence map›Paper›PMID 33386560›Full record

ArticleJournal of thrombosis and thrombolysis2021

Clinical validation of immunoassay HemosIL® AcuStar HIT-IgG (PF4-H) in the diagnosis of Heparin-induced thrombocytopenia.

Zeina Marashi-Sabouni, Caroline Vayne, Manal Ibrahim-Kosta, Catherine Guidon, Anderson Loundou, Eve Anne Guery, Pierre-Emmanuel Morange, Laurence Camoin-Jau

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of thrombosis and thrombolysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 1 country.

Zeina Marashi-SabouniLaboratoire d'Hématologie, La Timone Hospital, APHM, Boulevard Jean- Moulin, 13005, Marseille, France.
Caroline VayneService d'Hématologie Hémostase, Hôpital Trousseau, CHU de Tours, 37044, Tours, France.
Manal Ibrahim-KostaLaboratoire d'Hématologie, La Timone Hospital, APHM, Boulevard Jean- Moulin, 13005, Marseille, France.
Catherine GuidonDepartment of Anaesthesiology and Critical Care Medicine, University Hospital Timone, Marseille, France.
Anderson LoundouBiostatistic and Public Health Department, La Timone Hospital, Marseille, France.
Eve Anne GueryService d'Hématologie Hémostase, Hôpital Trousseau, CHU de Tours, 37044, Tours, France.
Pierre-Emmanuel MorangeLaboratoire d'Hématologie, La Timone Hospital, APHM, Boulevard Jean- Moulin, 13005, Marseille, France.
Laurence Camoin-JauLaboratoire d'Hématologie, La Timone Hospital, APHM, Boulevard Jean- Moulin, 13005, Marseille, France. laurence.camoin@ap-hm.fr.ORCID http://orcid.org/0000-0003-4681-626X
Inserm · FRCentre Hospitalier Universitaire de Tours · FRHôpital de la Timone · FRMéditerranée Infection Foundation · FRUniversité de Tours · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Heparin induced thrombocytopenia (HIT) is a life and limb-threatening complication of heparin exposure. The misdiagnosis of this disease can have major consequences on the patients. The objective of this study was to evaluate a diagnostic strategy that combines the 4Ts score with the result of HemosIL® AcuStar HIT-IgG (PF4-H) to confirm the diagnosis of HIT. Citrated plasmas from 1300 patients with suspicion of HIT were analyzed with a fully automated quantitative chemiluminescent immunoassay (HemosIL® AcuStar HIT-IgG (PF4/H)). If the IgG anti-PF4/H antibodies were positive (cut-off, 1 U/mL), HIT diagnosis was confirmed using functional tests. In total, 1300 samples of consecutive patients were enrolled, 94 (7.2%) of which gave positive results in HemosIL® AcuStar-IgG. HIT was diagnosed in 65 out of these patients, corresponding to a prevalence of 5%. Using ROC curve analysis, patients were divided into three groups according to their titer of antibodies. Higher values of the IgG (PF4-H) were associated with increased probability of HIT, and the diagnostic specificity was greatly increased using the combination of a 4Ts score > 3 and a positive titer ≥ 3.25 U/mL. Importantly, the diagnostic specificity is 100% when the titer is > 12.40 U/mL. We demonstrated that higher values of Anti PF4/H Antibodies were associated with a high probability of having HIT. A titer of HemosIL® IgG (PF4-H) > 12.40 U/mL has a specificity of 100% which should no require a functional test to confirm the diagnosis of HIT.

Indexed as

ThrombocytopeniaAnticoagulantsHeparinHumansImmunoassayImmunoglobulin GPlatelet Factor 4ROC CurveAnticoagulantsHeparinImmunoglobulin GPlatelet Factor 44 T scoreChemiluminescentHeparinHeparin induced thrombocytopeniaImmunoassay

Identifiers

PMID33386560
OpenAlexW3115751320

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked