Evidence map›Paper›PMID 33385544›Full record

ArticleNeuroImage2021

Fast computational optimization of TMS coil placement for individualized electric field targeting.

Luis J Gomez, Moritz Dannhauer, Angel V Peterchev

Abstract read
In one paragraph

Article in NeuroImage, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 58 papers.

0numbers the graph read from it
0cells of the map it votes in
58citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

58 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Virtual Neuronavigation for Parcel-guided TMS.medRxiv : the preprint server for health sciences · 2025
    Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Luis J GomezDepartment of Psychiatry and Behavioral Sciences, Duke University, 40 Duke Medicine Circle, Box 3620 DUMC, Durham, NC 27710, USA. Electronic address: ljgomez@purdue.edu.
Moritz DannhauerDepartment of Psychiatry and Behavioral Sciences, Duke University, 40 Duke Medicine Circle, Box 3620 DUMC, Durham, NC 27710, USA. Electronic address: moritz.dannhauer@duke.edu.
Angel V PeterchevDepartment of Psychiatry and Behavioral Sciences, Duke University, 40 Duke Medicine Circle, Box 3620 DUMC, Durham, NC 27710, USA; Department of Electrical and Computer Engineering, Duke University, NC 27708, USA; Department of Neurosurgery, Duke University, NC 27710, USA; Department of Biomedical Engineering, Duke University, NC 27708, USA. Electronic address: angel.peterchev@duke.edu.

Funding

Impact of Timing, Targeting, and Brain State on rTMS of Human and Non-Human PrimatesRF1MH114253 · NIMH · DUKE UNIVERSITY · PI SOMMER, MARC A · 2017 to 2017
$3.0M
Using fMRI-guided TMS to increase central executive function in older adults - Administrative SupplementU01AG050618 · NIA · DUKE UNIVERSITY · PI APPELBAUM, LAWRENCE G., CABEZA, ROBERTO · 2016 to 2019
$2.3M
Transcranial magnetic stimulation with enhanced focality and depth (fdTMS)RF1MH114268 · NIMH · DUKE UNIVERSITY · PI PETERCHEV, ANGEL V · 2017 to 2017
$1.6M
Accurate and reliable computational dosimetry and targeting for transcranial magnetic stimulationR00MH120046 · NIMH · PURDUE UNIVERSITY · PI GOMEZ, LUIS JAVIER · 2020 to 2022
$676k
Using fMRI-guided TMS to increase central executive function in older adultsR01AG050618 · NIA · DUKE UNIVERSITY · PI APPELBAUM, LAWRENCE G., CABEZA, ROBERTO · 2015 to 2015
$497k
Accurate and reliable computational dosimetry and targeting for transcranial magnetic stimulationK99MH120046 · NIMH · DUKE UNIVERSITY · PI GOMEZ, LUIS JAVIER · 2019 to 2020
$168k
NIA NIH HHS U01 AG050618NIMH NIH HHS K99 MH120046NIMH NIH HHS R00 MH120046NIMH NIH HHS RF1 MH114253NIMH NIH HHS RF1 MH114268
6 · The paper itself

Abstract

backgroundDuring transcranial magnetic stimulation (TMS) a coil placed on the scalp is used to non-invasively modulate activity of targeted brain networks via a magnetically induced electric field (E-field). Ideally, the E-field induced during TMS is concentrated on a targeted cortical region of interest (ROI). Determination of the coil position and orientation that best achieve this objective presently requires a large computational effort.

objectiveTo improve the accuracy of TMS we have developed a fast computational auxiliary dipole method (ADM) for determining the optimum coil position and orientation. The optimum coil placement maximizes the E-field along a predetermined direction or, alternatively, the overall E-field magnitude in the targeted ROI. Furthermore, ADM can assess E-field uncertainty resulting from precision limitations of TMS coil placement protocols.

methodADM leverages the electromagnetic reciprocity principle to compute rapidly the TMS induced E-field in the ROI by using the E-field generated by a virtual constant current source residing in the ROI. The framework starts by solving for the conduction currents resulting from this ROI current source. Then, it rapidly determines the average E-field induced in the ROI for each coil position by using the conduction currents and a fast-multipole method. To further speed-up the computations, the coil is approximated using auxiliary dipoles enabling it to represent all coil orientations for a given coil position with less than 600 dipoles.

resultsUsing ADM, the E-fields generated in an MRI-derived head model when the coil is placed at 5900 different scalp positions and 360 coil orientations per position (over 2.1 million unique configurations) can be determined in under 15 min on a standard laptop computer. This enables rapid extraction of the optimum coil position and orientation as well as the E-field variation resulting from coil positioning uncertainty. ADM is implemented in SimNIBS 3.2.

conclusionADM enables the rapid determination of coil placement that maximizes E-field delivery to a specific brain target. This method can find the optimum coil placement in under 15 min enabling its routine use for TMS. Furthermore, it enables the fast quantification of uncertainty in the induced E-field due to limited precision of TMS coil placement protocols, enabling minimization and statistical analysis of the E-field dose variability.

Indexed as

Computer SimulationElectromagnetic FieldsHumansModels, AnatomicTranscranial Magnetic StimulationAuxiliary dipole methodCoilE-fieldModelOptimalRanscranial magnetic stimulationReciprocityTargetingTMS

Identifiers

PMID33385544
PMCPMC7956218

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.