Heartbeat-Induced Corneal Axial Displacement and Strain Measured by High Frequency Ultrasound Elastography in Human Volunteers.

Sunny Kwok, Keyton Clayson, Nicholas Hazen, Xueliang Pan, Yanhui Ma, Andrew J Hendershot, Jun Liu

Open access · goldAbstract read
In one paragraph

Article in Translational vision science & technology, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.1field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Biomechanical Correlations Between the Cornea and the Optic Nerve Head.Investigative ophthalmology & visual science · 2024
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Sunny KwokDepartment of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
Keyton ClaysonDepartment of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
Nicholas HazenDepartment of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
Xueliang PanDepartment of Biomedical Informatics, The Ohio State University, Columbus, OH, USA.
Yanhui MaDepartment of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
Andrew J HendershotDepartment of Ophthalmology and Visual Science, The Ohio State University, Columbus, OH, USA.
Jun LiuDepartment of Biomedical Engineering, The Ohio State University, Columbus, OH, USA.
The Ohio State University · US

Funding

Ocular Pulse ElastographyR01EY025358 · NEI · OHIO STATE UNIVERSITY · PI LIU, JUN · 2016 to 2020
$2.0M
NEI NIH HHS R01 EY025358
6 · The paper itself

Abstract

Purpose: The purpose of this study was to establish in vivo data acquisition and processing protocols for repeatable measurements of heartbeat-induced corneal displacements and strains in human eyes, using a high-frequency ultrasound elastography method, termed ocular pulse elastography (OPE). Methods: Twenty-four volunteers with no known ocular diseases were recruited for this study. Intraocular pressure (IOP) and ocular pulse amplitude (OPA) were measured using a PASCAL Dynamic Contour Tonometer (DCT). An in vivo OPE protocol was developed to measure heartbeat-induced corneal displacements. Videos of the central 5.7 mm of the cornea were acquired using a 50-MHz ultrasound probe at 128 frames per second. The radiofrequency data of 1000 frames were analyzed using an ultrasound speckle tracking algorithm to calculate corneal displacements and quantify spectral and temporal characteristics. The intrasession and intersession repeatability of OPE- and DCT-measured parameters were also analyzed. Results: The in vivo OPE protocol and setup were successful in tracking heartbeat-induced corneal motion using high-frequency ultrasound. Corneal axial displacements showed a strong cardiac rhythm, with good intrasession and intersession repeatability, and high interocular symmetry. Corneal strain was calculated in two eyes of two subjects, showing substantially different responses. Conclusions: We demonstrated the feasibility of high-frequency ultrasound elastography for noninvasive in vivo measurement of the cornea's biomechanical responses to the intrinsic ocular pulse. The high intrasession and intersession repeatability suggested a robust implementation of this technique to the in vivo setting. Translational Relevance: OPE may offer a useful tool for clinical biomechanical evaluation of the cornea by quantifying its response to the intrinsic pulsation.

Indexed as

Elasticity Imaging TechniquesCorneaHealthy VolunteersHeart RateHumansTonometry, Ocularcorneal biomechanicscorneal displacementselastographyhigh frequency ultrasoundocular pulse

Identifiers

PMID33384887
PMCPMC7757631
OpenAlexW3115917090

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.