Evidence map›Paper›PMID 33383730›Full record

ArticleSensors (Basel, Switzerland)2020

Faulty Feeder Identification Based on Data Analysis and Similarity Comparison for Flexible Grounding System in Electric Distribution Networks.

Kangli Liu, Sen Zhang, Baorun Li, Chi Zhang, Biyang Liu, Hao Jin, Jianfeng Zhao

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Kangli LiuSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Sen ZhangSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Baorun LiSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Chi ZhangSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Biyang LiuSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Hao JinSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.
Jianfeng ZhaoSchool of Electrical Engineering, Southeast University, Nanjing 210096, China.

Funding

Jiangsu Planned Projects for Postdoctoral Research Funds 2018K002BNational Natural Science Foundation of China 51807029Project funded by China Postdoctoral Science Foundation 2020T130094
6 · The paper itself

Abstract

Reliability and safety are the most important indicators in the electric system. When a ground fault occurs, the electrical equipment and personnel will be greatly threatened. Due to the zero-sequence voltage/current sensor networks applied in the system, the fault identification and diagnosis technology are developing rapidly, including the application of ground fault suppression. A flexible grounding system (FGS) is a new technology applied to arc extinguishing in medium and high voltage electric distribution networks. Its characteristic is that when the single-phase ground fault occurs, the power-electronic-based device is put into the electric system to compensate and suppress the ground point current to be close to zero in a very short time. In order to implement the above process, the corresponding faulty feeder identification method needs to meet the requirements of rapidity and accuracy. In this article, based on the real-time sampled data from the zero-sequence current/voltage sensors, an improved faulty feeder identification method combining wavelet packet transform (WPT) and grey T-type correlation degree is proposed, which features both accuracy and rapidity. The former is used to reconstruct the transient characteristic signal, and the latter is responsible for calculating and comparing the similarity of relative variation trend. Simulation results verify the rationality and effectiveness of the proposed method and analysis.

Indexed as

data analysiselectric distribution networksfaulty feeder identificationflexible grounding systemgrey T-type correlation degreesimilarity comparisonwavelet packet transform

Identifiers

PMID33383730
PMCPMC7795609

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.