Comparison study of the axial length measured using the new swept-source optical coherence tomography ANTERION and the partial coherence interferometry IOL Master.

Kook Young Kim, Gon Soo Choi, Min Seok Kang, Ungsoo Samuel Kim

Open access · goldAbstract readComparative Study
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
22citing papers in PubMed, 1 pooled it
3.0field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

22 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Comparison of 2 modern swept-source optical biometers-IOLMaster 700 and Anterion.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Repeatability of a new swept-source optical coherence tomographer and agreement with other three optical biometers.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2022
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Kook Young KimKim's Eye Hospital, Seoul, Korea.
Gon Soo ChoiKim's Eye Hospital, Seoul, Korea.
Min Seok KangKim's Eye Hospital, Seoul, Korea.ORCID 0000-0001-5433-3706
Ungsoo Samuel KimKim's Eye Hospital, Seoul, Korea.ORCID 0000-0003-2373-6240
Kim's Eye Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare a biometer using swept-source optical coherence tomography (SS-OCT) with a partial coherence interferometry (PCI)-based biometer in measurements of two ocular biometry parameters, i.e., the axial length and anterior cornea curvature.

methodsWe compared the two biometers SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOL Master, Carl Zeiss Meditec, Jena, Germany) in terms of the axial length (AL) and corneal curvature (K) measurements of 175 eyes. Paired t-tests were used to compare the two biometers. Agreement between the biometers was evaluated using the Bland-Altman method.

resultsThe mean age was 36.0 ± 25.6 years (range: 5 to 85 years). The mean axial length was 24.42 ± 0.13 mm for SS-OCT and 24.45 ± 0.14 mm for PCI. The mean corneal curvature was significantly different between the two biometry in flat K (K1) but not in steep K (K2). The limit of agreement was -0.15 to 0.21 in the axial length, -1.18 to 0.83 in K1, and -1.06 to 0.95 in K2. All above ocular biometric measurements between SS-OCT and PCI correlated significantly (Pearson's correlation, p<0.001).

conclusionsThe axial length measured using SS-OCT is useful in clinical practice. It shows a good correlation and agreement with that measured using PCI. However, the axial length and corneal curvature measured using SS-OCT cannot be used interchangeably with that measured using PCI in clinical practice.

Indexed as

AdolescentAdultAgedAged, 80 and overAxial Length, EyeChildCorneaFemaleHumansInterferometryMaleMiddle AgedRetrospective StudiesTomography, Optical CoherenceYoung Adult

Identifiers

PMID33382814
PMCPMC7775111
OpenAlexW3115278878

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.