ArticleJournal of anatomy2021
Asymmetry of the pelvic ring evaluated by CT-based 3D statistical modeling.
Article in Journal of anatomy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Sex differences in hip bone and sacrum morphology: a geometric morphometric analysis.International journal of legal medicine · 2026Article
- The Standing Forward Flexion Test in Manual Therapy: A Critical Review and a Functional Reinterpretation.Cureus · 2026Review
- Preoperative planning technique for anterior pelvis percutaneous intramedullary screw fixation.OTA international : the open access journal of orthopaedic trauma · 2025Article
- Pelvic asymmetry in children with neuromuscular scoliosis: a computed tomography-based 3D analysis.Spine deformity · 2025Article
- Evaluation of the superior pubic ramus and supra acetabular corridors using statistical shape modelling.Surgical and radiologic anatomy : SRA · 2024Article
- Comparison of clinical and radiographic outcomes of bilateral versus unilateral ramus fixation in straddle fractures with posterior pelvic ring injury.Archives of orthopaedic and trauma surgery · 2024Article
- Clinical Workflow Algorithm for Preoperative Planning, Reduction and Stabilization of Complex Acetabular Fractures with the Support of Three-Dimensional Technologies.Journal of clinical medicine · 2024Article
- Analyzing Pelvic Asymmetry by Sex and Ancestry: Insights From an Osteological Collection.Cureus · 2024Article
- A Novel Approach of Customized Pelvic Implant Design Based on Symmetrical Analysis and 3D Printing.3D printing and additive manufacturing · 2023Article
- Development of a Statistical Shape Model and Assessment of Anatomical Shape Variations in the Hemipelvis.Journal of clinical medicine · 2023Article
- Asymmetry of the pelvis in Polish young adults.Frontiers in psychology · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The human pelvis is a complex anatomical structure that consists of the innominate bones, sacrum and coccyx to form the pelvic ring. Even though considered to be a symmetric entity, asymmetry of the pelvic ring (APR) might occur to alter its anatomy, function, or biomechanics or to impact assessment and treatment of clinical cases. APR and its assessment is complicated by the intricate anatomy of the pelvic ring. There is only limited information and understanding about APR with no established evaluation methods existing. The objective of the present study was to adopt CT-based 3D statistical modeling and analysis to assess APR within the complex anatomy of the pelvic ring. We were interested to establish a better understanding of APR with knowledge and applications transferred to human anatomy, related research, and development subjects and to clinical settings. A series of 150 routine, clinical, pelvic CT protocols of European and Asian males and females (64 ± 15 (20-90) years old) were post-processed to compute gender- and ancestry-specific 3D statistical models of the pelvic ring. Evaluations comprised principal component analysis (PCA) that included size, shape, and asymmetry patterns and their variations to be assessed. Four different CT-based 3D statistical models of the entire pelvic ring were computed according to the gender and ancestry specific groups. PCA mainly displayed size and shape variations. Examination of additional PCA modes permitted six distinct asymmetry patterns to be identified. They were located at the sacrum, iliac crest, pelvic brim, pubic symphysis, inferior pubic ramus, and near to the acetabulum. Accordingly, the pelvic ring demonstrated not to be entirely symmetric. Assessment of its asymmetry proved to be a challenging task. Using CT-based 3D statistical modeling and PCA, we identified six distinct APRs that were located at different anatomical regions. These regions are more prone to APRs than other sites. Minor asymmetry patterns have to be distinguished from the distinct APRs. Side differences with regard to size, shape, and/or position require to be taken into account. APRs may be due different load mechanisms applied via spine or lower extremity or locally. There is a need for simpler and efficient, yet reliable methods to be routinely transferred to human anatomy, related research, and development subjects and to clinical settings.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.