Evidence map›Paper›PMID 33378405›Full record

ArticlePloS one2020

Effect of different designs of interspinous process devices on the instrumented and adjacent levels after double-level lumbar decompression surgery: A finite element analysis.

Hao-Ju Lo, Hung-Ming Chen, Yi-Jie Kuo, Sai-Wei Yang

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 19 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Article
  6. Evaluating 5-year outcomes of interlaminar devices as an adjunct to decompression for symptomatic lumbar spinal stenosis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2023
    Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Hao-Ju LoDepartment of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.ORCID 0000-0003-4868-6403
Hung-Ming ChenDepartment of Orthopedic Surgery, Ren-Ai Branch of Taipei City Hospital, Taipei, Taiwan.
Yi-Jie KuoDepartment of Orthopedic Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan.
Sai-Wei YangDepartment of Biomedical Engineering, National Yang-Ming University, Taipei, Taiwan.ORCID 0000-0001-6488-2741
National Yang Ming Chiao Tung University · TWTaipei City Hospital · TWWan Fang Hospital · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, various designs and material manufactured interspinous process devices (IPDs) are on the market in managing symptomatic lumbar spinal stenosis (LSS). However, atraumatic fracture of the intervening spinous process has been reported in patients, particularly, double or multiple level lumbar decompression surgery with IPDs. This study aimed to biomechanically investigate the effects of few commercial IPDs, namely DIAMTM, CoflexTM, and M-PEEK, which were implanted into the L2-3, L3-4 double-level lumbar spinal processes. A validated finite element model of musculoskeletal intact lumbar spinal column was modified to accommodate the numerical analysis of different implants. The range of motion (ROM) between each vertebra, stiffness of the implanted level, intra stress on the intervertebral discs and facet joints, and the contact forces on spinous processes were compared. Among the three implants, the Coflex system showed the largest ROM restriction in extension and caused the highest stress over the disc annulus at the adjacent levels, as well as the sandwich phenomenon on the spinous process at the instrumented levels. Further, the DIAM device provided a superior loading-sharing between the two bridge supports, and the M-PEEK system offered a superior load-sharing from the superior spinous process to the lower pedicle screw. The limited motion at the instrumented segments were compensated by the upper and lower adjacent functional units, however, this increasing ROM and stress would accelerate the degeneration of un-instrumented segments.

Indexed as

Biomechanical PhenomenaDecompression, SurgicalFinite Element AnalysisHumansLumbar VertebraeRange of Motion, ArticularSpinal Stenosis

Identifiers

PMID33378405
PMCPMC7773253
OpenAlexW3118018595

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.