ArticleHealthcare (Basel, Switzerland)2020
A Minimally Invasive Technique for Short Spiral Implant Insertion with Contextual Crestal Sinus Lifting in the Atrophic Maxilla: A Preliminary Report.
Article in Healthcare (Basel, Switzerland), 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06759246 (Short Implant Placement for Single-Tooth Rehabilitation in the Atrophic Posterior Maxilla), which is not on this map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Short Implant Placement for Single-Tooth Rehabilitation in the Atrophic Posterior Maxilla
Who cites it
7 citing papers in PubMed, 9 citations in OpenAlex.
- Real-Time Motion Compensation for Dynamic Dental Implant Surgery.Journal of clinical medicine · 2025Article
- Immediate Loading of Implants-Supported Fixed Partial Prostheses in Posterior Regions: A Systematic Review.Dentistry journal · 2025Review
- Survival Rates of Short Dental Implants (≤6 mm) Used as an Alternative to Longer (>6 mm) Implants for the Rehabilitation of Posterior Partial Edentulism: A Systematic Review of RCTs.Dentistry journal · 2024Review
- Partial Implant Rehabilitations in the Posterior Regions of the Jaws Supported by Short Dental Implants (7.0 mm): A 7-Year Clinical and 5-Year Radiographical Prospective Study.Journal of clinical medicine · 2024Article
- Computer-Aided Design/Computer-Aided Manufacturing of Customized Abutment for Rehabilitating a Malpositioned Implant Using Digital Flow: A Case Report.Healthcare (Basel, Switzerland) · 2023Article
- Article
- Clinical Effect and Aesthetic Evaluation of Minimally Invasive Implant Therapy.Emergency medicine international · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The most recently reported techniques for the rehabilitation of the atrophic posterior maxilla are increasingly less invasive, as they are generally oriented to avoid sinus floor elevation with lateral access. The authors describe a mini-invasive surgical technique for short spiral implant insertion for the prosthetic rehabilitation of the atrophic posterior maxilla, which could be considered a combination of several previously described techniques based on the under-preparation of the implant site to improve fixture primary stability and crestal approach to the sinus floor elevation without heterologous bone graft. Eighty short spiral implants were inserted in the molar area of the maxilla in patients with 4.5-6 mm of alveolar bone, measured on pre-operative computed tomography. The surgical technique involved careful drilling for the preparation of implant sites at differentiated depths, allowing bone dislocation in the apical direction, traumatic crestal sinus membrane elevation, and insertion of an implant (with spiral morphology) longer than pre-operative measurements. Prostheses were all single crowns. In all cases, a spiral implant 2-4 mm longer than the residual bone was placed. Only two implants were lost due to peri-implantitis but subsequently replaced and followed-up. Bone loss values around the implants after three months (at the re-opening) ranged from 0 to 0.6 mm, (median value: 0.1 mm), while after two years, the same values ranged from 0.4 to 1.3 mm (median value: 0.7 mm). Clinical post-operative complications did not occur. After ten years, no implant has been lost. Overall, the described protocol seems to show good results in terms of predictability and patient compliance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.